Force replace of same drive in SVM

From: Jonathan Birchall (Jonathan.Birchall@Xchanging.com)
Date: Mon Apr 02 2007 - 07:27:38 EDT


Hello,

We have the situation below, with c3t11d0s0 being failed (format sees
drive as failed) but c4t3d0s0 appears to be fine.

Is there a way to force SVM to reset the status of d27 ?

d7: Mirror

    Submirror 0: d17

      State: Needs maintenance

    Submirror 1: d27

      State: Needs maintenance

    Pass: 1

    Read option: roundrobin (default)

    Write option: parallel (default)

    Size: 283685355 blocks

d17: Submirror of d7

    State: Needs maintenance

    Invoke: metareplace d7 c3t11d0s0 <new device>

    Size: 283685355 blocks

    Stripe 0: (interlace: 32 blocks)

      Device Start Block Dbase State Hot Spare

      c3t8d0s0 0 No Okay

      c3t9d0s0 0 No Okay

      c3t10d0s0 0 No Okay

      c3t11d0s0 0 No Maintenance

d27: Submirror of d7

    State: Needs maintenance

    Invoke: after replacing "Maintenance" components:

            metareplace d7 c4t3d0s0 <new device>

    Size: 283685355 blocks

    Stripe 0: (interlace: 32 blocks)

      Device Start Block Dbase State Hot Spare

      c4t0d0s0 0 No Okay

      c4t1d0s0 0 No Okay

      c4t2d0s0 0 No Okay

      c4t3d0s0 0 No Last Erred

Solaris 5.8

Disk Suite 4.2.1

---- BEGIN SSH2 PUBLIC KEY ----

Comment: "rsa-key-jonathan-birchall"

AAAAB3NzaC1yc2EAAAABJQAAAIEAs387ItDu/iBnKlP6R9PO9G2ukIDXYkeD2Wg7

zq7bdVNWQNIhETRJ+aj7DOiAEOEer7ox8RoNiFXCsoeNvzmuZu6mHzJnCbudGsa1

HL30O2WVY7UVrigIFsXxSZ3kL3GwlsyaqUADgWIEO2pkNtq5QaN7qDkHBliI63fB

u/Omv+c=

---- END SSH2 PUBLIC KEY ----

[demime 1.01b removed an attachment of type text/x-vcard which had a name of Jonathan Birchall.vcf]
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers