SUMMARY: RAID 10 (1+0) with Solstice Disksuite

From: Michael Hale (mhale@transcomus.com)
Date: Tue Jan 30 2007 - 14:28:36 EST


Thanks to Jeff Horwitz, Matthew Stier, Darren Dunham, and KR
(rossman@columbia.edu)

Turns out that SDS/SVM optimizes new RAID 0+1 volumes into RAID 1+0
just as long as the number of columns in each of the mirrored strips
is the same and the sized of the physical disk slices in each column
is the same, even though there is no difference in it's outward
appearance.

Also, Matthew Stier provided this link, which verifies that this is
indeed the case:

http://chrismiles.info/unix/sun/dsraid10.txt

--