Dear managers,
thanks to the many responses I got for my "SC password for V490"
posting. I am not completely through with the issue yet. But they made
clear that RSC is unconfigured by default and that one has to install
Solaris first via the serial port of the machine and setup RSC
afterwards. Here is what I did:
cd /opt/temp
mkdir SF490rsc
cd SF490rsc
unzip rsc2.2.3_packages_s9.zip
pkgadd -d .
/usr/platform/`uname -i`/rsc/rsc-config
I configured an IPAddress, gateway and an admin account.
eeprom | grep put-device
output-device=screen
input-device=keyboard
eeprom output-device=rsc-console
eeprom input-device=rsc-console
eeprom | grep put-device
output-device=rsc-console
input-device=rsc-console
I then logged in via telent to the Net RSC port which worked. I got a
rsc prompt and entered console
rsc> console
and here it is hanging!? No Control-C, no #. helps me further. What am
I missing?