From: Paul Coray (paul.coray@unibas.ch)
Date: Mon Nov 27 2006 - 03:53:06 EST
Hi all
I have a pair of Sun Sroredge 6120 Arrays. Firmware level is 3.1.4. Here
is the output of refresh -s:
Current Date and Time: Mon Nov 27 09:43:09 MET 2006
Next Scheduled Refresh: Mon Dec 25 01:13:15 MET 2006
Battery State Last Health Check Warranty Expiration
------- ------- ----------------------------
----------------------------
u1b1 normal Mon Nov 20 03:26:54 MET 2006 Thu Oct 20 14:55:10
MEST 2005
u1b2 normal Mon Nov 20 05:34:40 MET 2006 Thu Oct 20 14:55:19
MEST 2005
u2b1 normal Mon Nov 20 03:16:35 MET 2006 Thu Oct 20 17:45:48
MEST 2005
u2b2 normal Mon Nov 20 05:43:34 MET 2006 Thu Oct 20 17:46:00
MEST 2005
Output from fru stat:
POWER STATUS STATE SOURCE OUTPUT BATTERY TEMP FAN1 FAN2
------ ------- --------- ------ ------ ------- ------ ------ ------
u1pcu1 ready enabled line normal normal normal normal normal
u1pcu2 ready enabled line normal normal normal normal normal
u2pcu1 ready enabled line normal normal normal normal normal
u2pcu2 ready enabled line normal normal normal normal normal
-> warranty expired a year ago, but battery seems still ok. A few weeks
ago at the Sun Hotline, an engineer told me, I should only exchange the
batteries when I am told to do so by syslog messages, i.e. when the
health check would fail.
What is to believe: The warranty date or the health check? Best practice?
Thanks in advance. Will summarize
Paul
-- Paul Coray Administrator Server und Netzwerk Oeffentliche Bibliothek der Universitaet Basel EDV-Abteilung Schoenbeinstrasse 18-20 CH-4056 Basel Tel: +41 61 267 05 13 Fax: +41 61 267 31 03 mailto:paul.coray@unibas.ch http://www.ub.unibas.ch _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagers