Subject: Solaris 10 Veritas 4.1 Error identification assistance. Correct Answer

From: Kontizas Demostenis (kdemostenis@gmail.com)
Date: Tue Aug 01 2006 - 17:22:20 EDT


Original Issue:

VxVM vxdisk ERROR V-5-1-684 IPC failure: Configuration daemon is not
accessible
bash-3.00# vxconfigd

VxVM vxconfigd ERROR V-5-1-0 Bus error - core dumped
==============================================================

Fix:

This is the correct fix for that problem. Thank you for your assistance.

a. Remove the corrupted /etc/vx/disk.info file:
# rm -f /etc/vx/disk.info

b. Restart vxconfigd:
# /sbin/vxconfigd -k

Please read these guidelines for different system combinations.

http://symantec.atgnow.com/availability/resultDisplay.do?gotoLink=2425&docType=1000&contextId=34836%3A2425.2446&clusterName=AvailabilityCluster&contentId=ff564640-25a1-4f50-80c5-a63c0b603eca&responseId=151ebb619686bec4%3A1b1fbf4%3A10ccb0143cd%3Ab6b&groupId=6&answerGroup=2&score=365&page=http%3A%2F%2Fseer.support.veritas.com%2Fdocs%2F279364.htm&result=1&excerpt=%23+ldd+%2Fsbin%2Fvxconfigd&resultType=5000#

Kind regards,

Kontizas Demostenis
ETLCQA SAN-QA