summary V210 error

From: Mike Carter (mike.c@altatechnologies.com)
Date: Tue May 16 2006 - 10:30:20 EDT


Big thanks to Graham Wood....

solved our V210 issue below with the following assistance

Gurus...can anyone shed light on this V210 issue at a customer site --- v210
showing error below....Thankd in advance for any help you folks can
offer....

I see that the "MB/SC" is "faulty" (from
/usr/platform/sun4u/sbin/prtdiag -v) but I am not sure what this is or what
part number I would need to replace.

Graham's reply and simple solutuion follows...thanks a mill!

IIRC this can be caused by the SC hanging. Try "scadm reset" (or whatever
the command is,
it's been about 6 months since I had access to one).

Thanks for all the replies...this group is great!

Michael Carter
Account Manager
Alta Technologies Inc
763-475-5327
800-546-2582 (327)
AIM mikec at alta
yahoo IM cartematalta