From: T.J. Hoo (tjhoo@hotmail.com)
Date: Sat Mar 11 2006 - 04:28:10 EST
Hi!
I have a Sun Cluster 3.1 configured for Solaris 9 (12/03).
The cluster has a Sun StorEdge 3510 array diskset.
The metastat shows that there is a submirror needs maintenance:
sogds/d160: Mirror
Submirror 0: sogds/d161
State: Okay
Submirror 1: sogds/d162
State: Needs maintenance
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 209694720 blocks (99 GB)
sogds/d161: Submirror of sogds/d160
State: Okay
Size: 209694720 blocks (99 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
d6s0 0 No Okay No
sogds/d162: Submirror of sogds/d160
State: Needs maintenance
Invoke: metareplace sogds/d160 d7s0 <new device>
Size: 209694720 blocks (99 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
d7s0 0 No Maintenance No
It said that I should invoke the command metareplace to replace it with a
new <new device>.
But how do I know what are the devices available?
I also tried to enable the slice by entering the following command,
# metareplace -s sogds -e sogds/d160 d7s0
metareplace: emanode-a: d7s0: No such file or directory
Do you what could be the problem?