wanted: PCI slot probe order for Sun V880

From: Sean Walmsley (sean.p.walmsley@opg.com)
Date: Tue Jul 02 2002 - 14:17:46 EDT


HARDWARE: SunFire V880 server
OS: Solaris 9

Can anyone tell me what the PCI slot probe order is on the
SunFire V880 server? There is a nice infodoc (27243) on the
probe order for the E450 (partially included below), but I
haven't been able to find anything similar for the V880.

I'm attempting to predict what controller id's will get
assigned based on HBA location.

Is there a way to determine this from the OpenBoot prompt
so that I don't need to post every time we purchase a new
type of machine :-) ?

I've searched the sunmanager archives, sunsolve and google
all with no success.

Thanks in advance,

---------------------------------------------------------------------
FROM SUN INFODOC 27243 (For the E450):

This order can be used to predict the controller
numbers. On an initial boot off of a Solaris 8 cdrom the OS will create
controller
numbers in the following order:

/pci@1f,4000/scsi@3 > internal 4 slot disk backplane
/pci@1f,4000/scsi@2 > RMA and external scsi port
/pci@1f,4000/device@4 > slot 10
/pci@1f,2000/device@1 > slot 5
/pci@4,4000/device@2 > slot 9
/pci@4,4000/device@3 > slot 8
/pci@4,4000/device@4 > slot 7
/pci@4,2000/device@1 > slot 6
/pci@6,4000/device@2 > slot 3
/pci@6,4000/device@3 > slot 2
/pci@6,4000/device@4 > slot 1
/pci@6,2000/device@1 > slot 4

---------------------------------------------------------------------

===============================================================
Sean Walmsley, Nuclear Analysis Dept., Ontario Power Generation
sean.p.walmsley@opg.com 416-592-4608 (V) 416-592-5528 (F)
700 University Ave (H11 G26), Toronto, Ontario, M5G 1X6, CANADA
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:24:33 EDT