SCSI Disk Errors - sense key: not ready

From: Wiest, Damian (dmwiest@rc2corp.com)
Date: Tue Jan 31 2006 - 09:24:52 EST


Greetings all,

I have a couple of IBM SCSI drives that are requiring maintenance on a
weekly basis. I have six 18GB drives installed in the first half of a D1000
array which is attached to a dual-channel Symbios SCSI card in an old E-250.
Four of the disks are from IBM (product number DDYST1835SUN18G, revision
S94A) and the other two are from Fujitsu (product number MAJ3182M SUN18G,
revision 0804). I have configured the disks as three, two-way mirrors under
SVM; one of the mirrors with IBM drives is logging errors. Here's a sample
entry from /var/adm/messages:

Jan 28 06:30:01 lcidev01 unix: WARNING: /pci@1f,4000/scsi@5,1/sd@2,0 (sd47):
Jan 28 06:30:01 lcidev01 Error for Command: write(10)
Error Level: Fatal
Jan 28 06:30:01 lcidev01 unix: Requested Block: 6137304
Error Block: 6137304
Jan 28 06:30:01 lcidev01 unix: Vendor: IBM
Serial Number: 00361EE587
Jan 28 06:30:01 lcidev01 unix: Sense Key: Not Ready
Jan 28 06:30:01 lcidev01 unix: ASC: 0x4 (<vendor unique code 0x4>), ASCQ:
0x1, FRU: 0x0
Jan 28 06:30:01 lcidev01 unix: WARNING: md: d112: write error on
/dev/dsk/c1t2d0s7
Jan 28 06:30:11 lcidev01 unix: WARNING: md: d112: /dev/dsk/c1t2d0s7 needs
maintenance

The disks typically begin exhibiting this behavior during periods of high
activity. I do have a couple of replacements lying around, but I'd like
some advice as to whether this problem is related to the drives, or if it's
indicative of a bigger problem before simply swapping them out.

TIA!

-Damian
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:38:47 EDT