hdd problem

From: Vladimir (mom@ngs.ru)
Date: Tue Jan 10 2006 - 06:59:16 EST


Hello Gurus!

I have Sun-Fire 480R running with Solaris 9 patched with last recommended
patch set.

I found the following:

Jan 5 12:00:44 host scsi: [ID 107833 kern.warning] WARNING:
/pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w2100000c50e2696d,0 (ssd0):
Jan 5 12:00:44 host Error for Command: write(10) Error
Level: Retryable
Jan 5 12:00:44 host scsi: [ID 107833 kern.notice] Requested Block:
106554736 Error Block: 106554736
Jan 5 12:00:44 host scsi: [ID 107833 kern.notice] Vendor: SEAGATE
Serial Number: 0421B7HP49
Jan 5 12:00:44 host scsi: [ID 107833 kern.notice] Sense Key: Hardware
Error
Jan 5 12:00:44 host scsi: [ID 107833 kern.notice] ASC: 0x15 (<vendor
unique code 0x15>), ASCQ: 0x1, FRU: 0x1
Jan 5 12:52:08 host qlc: [ID 686697 kern.info] NOTICE: Qlogic qlc(0): Loop
OFFLINE Jan 5 12:52:08 host qlc: [ID 686697 kern.info] NOTICE: Qlogic
qlc(0): Loop ONLINE Jan 5 12:52:12 host scsi: [ID 107833 kern.warning]
WARNING:
/pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w2100000c50e23bd1,0 (ssd1):
Jan 5 12:52:12 host Error for Command: write(10) Error
Level: Retryable
Jan 5 12:52:12 host scsi: [ID 107833 kern.notice] Requested Block:
143327051 Error Block: 143327051
Jan 5 12:52:12 host scsi: [ID 107833 kern.notice] Vendor: SEAGATE
Serial Number: 0421B7H663
Jan 5 12:52:12 host scsi: [ID 107833 kern.notice] Sense Key: Unit
Attention
Jan 5 12:52:12 host scsi: [ID 107833 kern.notice] ASC: 0x29 (power on,
reset, or bus reset occurred), ASCQ: 0x0, FRU: 0x3 Jan 5 12:52:12 host
scsi: [ID 107833 kern.warning] WARNING:
/pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w2100000c50e2696d,0 (ssd0):
Jan 5 12:52:12 host Error for Command: write(10) Error
Level: Retryable
Jan 5 12:52:12 host scsi: [ID 107833 kern.notice] Requested Block:
41756221 Error Block: 41756221
Jan 5 12:52:12 host scsi: [ID 107833 kern.notice] Vendor: SEAGATE
Serial Number: 0421B7HP49
Jan 5 12:52:12 host scsi: [ID 107833 kern.notice] Sense Key: Unit
Attention
Jan 5 12:52:12 host scsi: [ID 107833 kern.notice] ASC: 0x29 (power on,
reset, or bus reset occurred), ASCQ: 0x0, FRU: 0x3 Jan 9 08:00:31 host
scsi: [ID 107833 kern.warning] WARNING:
/pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w2100000c50e2696d,0 (ssd0):
Jan 9 08:00:31 host Error for Command: write(10) Error
Level: Retryable
Jan 9 08:00:31 host scsi: [ID 107833 kern.notice] Requested Block:
122865040 Error Block: 122865040
Jan 9 08:00:31 host scsi: [ID 107833 kern.notice] Vendor: SEAGATE
Serial Number: 0421B7HP49
Jan 9 08:00:31 host scsi: [ID 107833 kern.notice] Sense Key: Hardware
Error
Jan 9 08:00:31 host scsi: [ID 107833 kern.notice] ASC: 0x15 (<vendor
unique code 0x15>), ASCQ: 0x1, FRU: 0x1
Jan 9 08:00:36 host scsi: [ID 107833 kern.warning] WARNING:
/pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w2100000c50e2696d,0 (ssd0):
Jan 9 08:00:36 host Error for Command: write(10) Error
Level: Retryable
Jan 9 08:00:36 host scsi: [ID 107833 kern.notice] Requested Block:
122865072 Error Block: 122865072
Jan 9 08:00:36 host scsi: [ID 107833 kern.notice] Vendor: SEAGATE
Serial Number: 0421B7HP49
Jan 9 08:00:36 host scsi: [ID 107833 kern.notice] Sense Key: Media
Error
Jan 9 08:00:36 host scsi: [ID 107833 kern.notice] ASC: 0x3 (peripheral
device write fault), ASCQ: 0x0, FRU: 0x8

Is this a serious problem? Should I contact sun support?

Thank you in advance! I will summarize.

// Vladimir