SUMMARY: Problems bringing up domains in a E10000 - Panic Boot

From: Juan Carlos García Velasco (gvelasco@cuauhtemoc.edu.mx)
Date: Thu Dec 08 2005 - 20:13:13 EST


Hi again!

Thanks to Darren Dunham and Fabio for their answers, it's really amazing the
help I receive even that my problem was kind of easy.

The only thing I have to do is to type this commmand at the OBP:

<#8> ok boot /sbus@4c,0/QLGC,isp@0,10000/sd

After trying all of the devices showed at the

> <#8> ok show-disks
> a) /sbus@4c,0/SUNW,socal@1,0/sf@1,0/ssd
> b) /sbus@4c,0/SUNW,socal@1,0/sf@0,0/ssd
> c) /sbus@4c,0/QLGC,isp@0,10000/sd
> d) /sbus@48,0/SUNW,socal@1,0/sf@1,0/ssd
> e) /sbus@48,0/SUNW,socal@1,0/sf@0,0/ssd
> f) /sbus@48,0/QLGC,isp@0,10000/sd
> q) NO SELECTION
> <#8> ok

I got some errors but I think is one disk...

INIT: Command is respawning too rapidly. Check for possible errors.
id: SV "/usr/bin/srload -D -q"

WARNING: /sbus@4c,0/SUNW,socal@1,0/sf@0,0/ssd@w2200002037266d3c,0 (ssd10):
        Error for Command: load/start/stop Error Level: Retryable
        Requested Block: 0 Error Block: 0
        Vendor: SEAGATE Serial Number:
        Sense Key: Not Ready

WARNING: forceload of drv/atf failed
WARNING: forceload of misc/md_trans failed
WARNING: forceload of misc/md_raid failed
WARNING: forceload of misc/md_hotspares failed
WARNING: forceload of drv/atf failed
WARNING: forceload of drv/pln failed

Anyway, thanks for the help!

- Juan Carlos.

On Thu, 8 Dec 2005 18:17:33 -0500, Juan Carlos Garcma Velasco wrote
> Hi Managers,
>
> This is the first time I write to the list, I'm a kind of newbie
> using solaris and at work I have an E10000 server.
>
> So the big, big problem is that it stops working :( and all I know
> about bringing up the domains in the E10000 server doesn't work...
>
> Here is the output of some commands at the OBP:
>
> <#8> ok boot disk0 -r
> Rebooting with command: boot disk0 -r
> Boot device: /sbus@49,0/SUNW,qfe@0,8c00000 File and args: disk0 -r
> Timeout waiting for ARP/RARP packet
> 23a00 hostname: webaplic
> whoami: no domain name
> root server: sspaplic
> root directory: /cdrom/sol_7_1199_sparc_sun_srvr/s0/Solaris_2.7/Tools/Boot
> panic - boot: Could not mount filesystem.
> Program terminated
> <#8> ok
>
> <#8> ok boot disk1 -r
> Rebooting with command: boot disk1 -r
> Boot device: /sbus@49,0/SUNW,qfe@0,8c00000 File and args: disk1 -r
> Timeout waiting for ARP/RARP packet
> 23a00 hostname: webaplic
> whoami: no domain name
> root server: sspaplic
> root directory: /cdrom/sol_7_1199_sparc_sun_srvr/s0/Solaris_2.7/Tools/Boot
> panic - boot: Could not mount filesystem.
> Program terminated
> <#8> ok
>
> <#8> ok show-disks
> a) /sbus@4c,0/SUNW,socal@1,0/sf@1,0/ssd
> b) /sbus@4c,0/SUNW,socal@1,0/sf@0,0/ssd
> c) /sbus@4c,0/QLGC,isp@0,10000/sd
> d) /sbus@48,0/SUNW,socal@1,0/sf@1,0/ssd
> e) /sbus@48,0/SUNW,socal@1,0/sf@0,0/ssd
> f) /sbus@48,0/QLGC,isp@0,10000/sd
> q) NO SELECTION
> <#8> ok
>
> <#8> ok devalias
> net /sbus@49,0/SUNW,qfe@0,8c00000
> disk /sbus@48,0/QLGC,isp@0,10000/sd@0,0:a
> ttya /ssp-serial
>
ssa_b_example /sbus@40,0/SUNW,soc@0,0/SUNW,pln@b0000000,XXXXXX/SUNW
> ,ssd@0,0:a
>
ssa_a_example /sbus@40,0/SUNW,soc@0,0/SUNW,pln@a0000000,XXXXXX/SUNW
> ,ssd@0,0:a
> isp_example /sbus@40,0/QLGC,isp@0,10000/sd@0,0
> net_example /sbus@40,0/qec@0,20000/qe@0,0
> name aliases
> <#8> ok
>
> <#8> ok printenv boot-device
> boot-device
> = /sbus@48,0/SUNW,socal@0,0/sf@0,0/ssd@w22000020374f4c09,0:a
> disk diskbrd diskisp disksoc net <#8> ok
>
> <#8> ok printenv diag-device
> diag-device = disk diskbrd diskisp disksoc net
> <#8> ok
>
> <#8> ok probe-scsi-all
> This command may hang the system if a Stop-A or halt command
> has been executed. Please type reset-all to reset the system
> before executing this command.
> Do you wish to continue? (y/n) y
> /sbus@4c,0/QLGC,isp@0,10000
> Target 0
> Unit 0 Disk SEAGATE ST39103LCSUN9.0G034A9944632001
> Copyright (c) 1999 Seagate
> All rights reserved
> Target 1
> Unit 0 Disk SEAGATE ST39103LCSUN9.0G034A9944632967
> Copyright (c) 1999 Seagate
> All rights reserved
> Target e
> Unit 0 Processor SYMBIOS D1000 2 NvC SAF-TE1.00
>
> /sbus@48,0/QLGC,isp@0,10000
> <#8> ok
>
> As you can see I got an panic boot could not mount filesystem. I've
> not only the E10000 server I also have a disk array A5000 one of
> data and other for booting.
>
> I will really appreciate any idea or suggestion, and of course I
> will summarize my results. Thanks in advance.
>
> - Juan Carlos G. Velasco
> _______________________________________________
> sunmanagers mailing list
> sunmanagers@sunmanagers.org
> http://www.sunmanagers.org/mailman/listinfo/sunmanagers
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:37:36 EDT