From: Dan Girard (shadoboxer@mac.com)
Date: Tue Oct 11 2005 - 10:16:30 EDT
I never claim to be a storage admin but my job sometimes requires me to
learn the dark side of the force.
I digress,
After disk replacement with a supported Sun product, the drive is still
showing bad. However, the model # is not that of the new disk. Looks
like the array hasn't polled for any change of disks.
sccli> show disks
Ch Id Size Speed LD Status IDs Rev
----------------------------------------------------------------------------
0 0 N/A N/A ld0 BAD SEAGATE ST373307LSUN72G 0507
S/N 3HZ6NHA500007425
sccli> show drive-parameters
spin-up: disabled
reset-at-power-up: enabled
disk-access-delay: 15s
scsi-io-timeout: 15s
queue-depth: 32
polling-interval: 500ms
enclosure-polling-interval: 30s
auto-detect-swap-interval: disabled (should this be changed?)
smart: disabled
auto-global-spare: disabled
Any help? I checked online and there doesn't seem to be cmd to force a
media check and rebuild.
Dan Girard
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:32:39 EDT