From: Dave Martini 1 (martini@raider.llnl.gov)
Date: Mon Jun 20 2005 - 14:05:47 EDT
I have a 3310 stoage array with a single RAID controller in it.
I want to be notified when a disk failure occurs.
I didn't see anyting in the manual about the system emailing
when there is a disk problem on the 3310.
Does anyone know if there is an email notification built into
the 3310?
If not I was thinking of writing a script that would go into the
sccli utility and do a enclosure-status and output this to a file
although I can figure out how to output it to a file because I tried
this
sccli> show enclosure-status >/opt/filemane
but it didn't create the file it just output it to the screen.
Is it possible to output it to a file?
I see under he status column it says the word OK.
What will this change to if the status is not ok would it say
NOT OK?
I want to know what word to search for.
Any suggestions on how best to do this would be great.
The cli interfact has many options. Another is
sccli> show disks
Ch Id Size Speed LD Status IDs
-----------------------------------------------------------------------
0 0 68.37GB 160MB ld0 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8HJ
0 1 68.37GB 160MB ld0 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8NJ
0 2 68.37GB 160MB ld0 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8J3
0 3 68.37GB 160MB ld0 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8P5
0 4 68.37GB 160MB ld0 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8JJ
0 5 68.37GB 160MB ld0 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8JD
0 8 68.37GB 160MB ld0 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C9C0
0 9 68.37GB 160MB ld0 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8P9
0 10 68.37GB 160MB ld1 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8HV
0 11 68.37GB 160MB ld1 ONLINE FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8NC
0 12 68.37GB 160MB GLOBAL STAND-BY FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8NV
0 13 68.37GB 160MB GLOBAL STAND-BY FUJITSU MAP3735N SUN72G 0401
S/N 00Q0C8JB
Thank You
Dave Martini
LLNL
sccli> show enclosure-status
Ch Id Chassis Vendor Product ID Rev Package Status
-----------------------------------------------------------------
0 14 081476 SUN StorEdge 3310 A 1159 1159 OK
Enclosure Component Status:
Type Unit Status FRU P/N FRU S/N Add'l Data
------------------------------------------------------------------
Fan 0 OK 370-6776 GM02GJ --
Fan 1 OK 370-6776 GM02G7 --
PS 0 OK 370-6776 GM02GJ --
PS 1 OK 370-6776 GM02G7 --
Temp 0 OK 370-5524 081476 temp=23
Temp 1 OK 370-5524 081476 temp=22
Temp 2 OK 370-6776 GM02GJ temp=22
Temp 3 OK 370-5394 JK098Z temp=26
Temp 4 OK 370-5394 JK097T temp=26
Temp 5 OK 370-5524 081476 temp=21
Temp 6 OK 370-6776 GM02G7 temp=23
EMU 0 OK 370-5394 JK098Z
EMU 1 OK 370-5394 JK097T
DiskSlot 0 OK 370-5524 081476 addr=0,led=off
DiskSlot 1 OK 370-5524 081476 addr=1,led=off
DiskSlot 2 OK 370-5524 081476 addr=2,led=off
DiskSlot 3 OK 370-5524 081476 addr=3,led=off
DiskSlot 4 OK 370-5524 081476 addr=4,led=off
DiskSlot 5 OK 370-5524 081476 addr=5,led=off
DiskSlot 6 OK 370-5524 081476 addr=8,led=off
DiskSlot 7 OK 370-5524 081476 addr=9,led=off
DiskSlot 8 OK 370-5524 081476 addr=10,led=off
DiskSlot 9 OK 370-5524 081476 addr=11,led=off
DiskSlot 10 OK 370-5524 081476 addr=12,led=off
DiskSlot 11 OK 370-5524 081476 addr=13,led=off
Enclosure SCSI Channel Type: single-bus
sccli>
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers