Summary: urgent: cfgadm configure problem

From: Michael Segale (msegale@us.ibm.com)
Date: Wed Jun 15 2005 - 12:17:55 EDT


All,
      Thanks to all that responded.

cfgadm -c configure c4 c6

Is the right answer. I had other issues so this didn't work for me until I
solved the other issues.

Michael Segale Unix Sys Admin

----- Forwarded by Michael Segale/Newark/IBM on 06/15/2005 12:14 PM -----
                                                                           
             Michael
             Segale/Newark/IBM
             @IBMUS To
             Sent by: sunmanagers@sunmanagers.org
             sunmanagers-bounc cc
             es@sunmanagers.or
             g Subject
                                       urgent: cfgadm configure problem
                                                                           
             06/14/2005 02:54
             PM
                                                                           
                                                                           
                                                                           

All,
      I need the cfgadm command that will bring c4 and c6 below online

# cfgadm
Ap_Id Type Receptacle Occupant
Condition
c0 scsi-bus connected configured
unknown
c1 scsi-bus connected configured
unknown
c2 scsi-bus connected unconfigured
unknown
c3 fc-fabric connected configured
unknown
c4 fc connected unconfigured
unknown
c5 fc-fabric connected configured
unknown
c6 fc connected unconfigured
unknown

Michael Segale Unix Sys Admin
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:30:54 EDT