sun fire 1280 issue

From: nikhil vr (nikhilvr@hotmail.com)
Date: Wed Apr 20 2005 - 06:38:21 EDT


Hi while running LOM>show logs following errors occuring
SafariPortError2 and 0x1 L2 parity error for DTransID

lom>showdate

Tue Apr 19 23:31:53 PDT 2005 lom>showlogs Wed Mar 16 02:43:11 c08u5cl114
lom: [ID 967136 local0.notice] Domain Reboot A: Initiating keyswitch: on,
domain A. Wed Mar 16 02:43:11 c08u5cl114 lom: [ID 967136 local0.notice]
Domain Reboot A: Initiating keyswitch: on, domain A. Wed Mar 16 02:48:24
c08u5cl114 lom: [ID 967136 local0.notice] Domain Reboot A: Initiating
keyswitch: on, domain A. Wed Mar 16 02:48:24 c08u5cl114 lom: [ID 967136
local0.notice] Domain Reboot A: Initiating keyswitch: on, domain A. Wed
Mar 16 05:03:52 c08u5cl114 lom: [ID 967136 local0.notice] Domain Reboot
A: Initiating keyswitch: on, domain A. Wed Mar 16 05:03:52 c08u5cl114
lom: [ID 967136 local0.notice] Domain Reboot A: Initiating keyswitch: on,
domain A. Wed Mar 30 22:58:52 c08u5cl114 lom: [ID 967136 local0.notice]
Domain Reboot A: Initiating keyswitch: on, domain A. Wed Mar 30 22:58:52
c08u5cl114 lom: [ID 967136 local0.notice] Domain Reboot A: Initiating
keyswitch: on, domain A. Wed Mar 30 23:16:41 c08u5cl114 lom: [ID 967136
local0.notice] Domain Reboot A: Initiating keyswitch: on, domain A. Wed
Mar 30 23:16:41 c08u5cl114 lom: [ID 967136 local0.notice] Domain Reboot
A: Initiating keyswitch: on, domain A. Thu Mar 31 00:28:16 c08u5cl114
lom: [ID 967136 local0.notice] Domain Reboot A: Initiating keyswitch: on,
domain A. Thu Mar 31 00:28:16 c08u5cl114 lom: [ID 967136 local0.notice]
Domain Reboot A: Initiating keyswitch: on, domain A. Thu Apr 07 05:50:24
c08u5cl114 lom: [ID 967136 local0.notice] Domain Reboot A: Initiating
keyswitch: on, domain A. Thu Apr 07 05:50:24 c08u5cl114 lom: [ID 967136
local0.notice] Domain Reboot A: Initiating keyswitch: on, domain A. Mon
Apr 11 23:45:51 c08u5cl114 lom: [ID 967136 local0.notice] Domain Reboot
A: Initiating keyswitch: on, domain A. Mon Apr 11 23:45:51 c08u5cl114
lom: [ID 967136 local0.notice] Domain Reboot A: Initiating keyswitch: on,
domain A. Tue Apr 12 07:59:48 c08u5cl114 lom: [ID 967136 local0.notice]
Domain Reboot A: Initiating keyswitch: on, domain A. Tue Apr 12 07:59:48
c08u5cl114 lom: [ID 967136 local0.notice] Domain Reboot A: Initiating
keyswitch: on, domain A. Thu Apr 14 08:47:10 c08u5cl114 lom: [ID 967136
local0.notice] Domain Reboot A: Initiating keyswitch: on, domain A. Thu
Apr 14 08:47:10 c08u5cl114 lom: [ID 967136 local0.notice] Domain Reboot
A: Initiating keyswitch: on, domain A. Fri Apr 15 16:50:37 c08u5cl114
lom: [ID 967136 local0.notice] Domain Reboot A: Initiating keyswitch: on,
domain A. Fri Apr 15 16:50:37 c08u5cl114 lom: [ID 967136 local0.notice]
Domain Reboot A: Initiating keyswitch: on, domain A. Tue Apr 19 09:28:11
c08u5cl114 lom: [ID 920266 local0.crit] ErrorMonitor: Domain A has a
SYSTEM ERROR Tue Apr 19 09:28:11 c08u5cl114 lom: [ID 920266 local0.crit]
ErrorMonitor: Domain A has a SYSTEM ERROR Tue Apr 19 09:28:11 c08u5cl114
lom: [ID 892466 local0.error] /N0/RP2 encountered the first error Tue Apr
19 09:28:12 c08u5cl114 lom: [ID 125868 local0.error] /RP2/sdc0: >>>
SafariPortError2[0x220] : 0x00088008 FE [15:15] : 0x1 AccParL2ErrDT
[19:19] : 0x1 ParL2ErrDT [03:03] : 0x1 L2 parity error for DTransID Tue
Apr 19 09:28:12 c08u5cl114 lom: [ID 197878 local0.error] Tue Apr 19
09:28:12 c08u5cl114 lom: [ID 719549 local0.error] SdcAsic reported first
error on /N0/SB2 Tue Apr 19 09:28:12 c08u5cl114 lom: [ID 442488
local0.error] /SB2/sdc0: >>> L2CheckError[0x6150] : 0x00208020
A0B0DiffErrDT [05:05] : 0x1 L2 ports A0 and B0 mismatched (DTransID) FE
[15:15] : 0x1 AccA0B0DiffErrDT [21:21] : 0x1 Tue Apr 19 09:28:22
c08u5cl114 lom: [ID 638464 local0.error] [AD] Event:
SFV1280.ASIC.SDC.PAR_L2_ERR_DT.60153032 CSN: DomainID: A ADInfo:
1.SCAPP.18.0 Time: Tue Apr 19 09:27:30 PDT 2005 FRU-List-Count: 2;
FRU-PN: 5405467; FRU-SN: A28029; FRU-LOC: /N0/SB2 FRU-PN: 5404974;
FRU-SN: 025199; FRU-LOC: /N0/RP2 Recommended-Action: Service action
required Tue Apr 19 09:28:22 c08u5cl114 lom: [ID 638464 local0.error]
[AD] Event: SFV1280.ASIC.SDC.PAR_L2_ERR_DT.60153032 CSN: DomainID: A
ADInfo: 1.SCAPP.18.0 Time: Tue Apr 19 09:27:30 PDT 2005 FRU-List-Count:
2; FRU-PN: 5405467; FRU-SN: A28029; FRU-LOC: /N0/SB2 FRU-PN: 5404974;
FRU-SN: 025199; FRU-LOC: /N0/RP2 Recommended-Action: Service action
required Tue Apr 19 09:28:22 c08u5cl114 lom: [ID 764738 local0.crit] A
fatal condition is detected on Domain A. Initiating automatic restoration
for this domain. Tue Apr 19 09:28:22 c08u5cl114 lom: [ID 764738
local0.crit] A fatal condition is detected on Domain A. Initiating
automatic restoration for this domain. Tue Apr 19 09:28:22 c08u5cl114
lom: [ID 273180 local0.notice] A: CycleKeyswitch: Initiating keyswitch:
off, domain A. Tue Apr 19 09:28:22 c08u5cl114 lom: [ID 273180
local0.notice] A: CycleKeyswitch: Initiating keyswitch: off, domain A.
Tue Apr 19 09:28:57 c08u5cl114 lom: [ID 123804 local0.notice] SysEvent 5
/N0/PS0, power state, Off (5,0) Tue Apr 19 09:28:57 c08u5cl114 lom: [ID
124060 local0.notice] SysEvent 5 /N0/PS1, power state, Off (5,0) Tue Apr
19 09:28:58 c08u5cl114 lom: [ID 124316 local0.notice] SysEvent 5 /N0/PS2,
power state, Off (5,0) Tue Apr 19 09:28:59 c08u5cl114 lom: [ID 605643
local0.notice] /N0/FT0, fan speed, Off (4,0) Tue Apr 19 09:28:59
c08u5cl114 lom: [ID 324119 local0.warning] CAUTION: Physically removing
the last power supply will cause the system to lose power. Tue Apr 19
09:28:59 c08u5cl114 lom: [ID 124572 local0.notice] SysEvent 5 /N0/PS3,
power state, Off (5,0) Tue Apr 19 09:28:59 c08u5cl114 lom: [ID 504858
local0.error] Device voltage probl RegardsNikhil

------------------------------------------------------------------------

The coolest stars! The hottest gossip! Get the spice@MSN Movies!
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers