more on V880 weirdness

From: NetComrade (netcomrade@bookexchange.net)
Date: Fri Apr 01 2005 - 03:10:33 EST


diag-switch? set to false, diag-level set to min, key switch set to normal
and its still doing diagnostics

Is this even possible?

We reinstalled OS. Re-applied patches.. Re-installed Veritas
software.. reboot.. Hangs on

Rebooting with command: boot
Boot device: /pci@8,600000/SUNW,qlc@2/fp@0,0/disk@w21000004cf8a4148,0:a
File and args:
SunOS Release 5.8 Version Generic_117350-21 64-bit
Copyright 1983-2003 Sun Microsystems, Inc. All rights reserved.
-

And then we are forced to turn the key. We are stuck in diagnostic hell!
(normally it should take about 5 mins to reboot, but since the machine
forces itself into diag, it takes about 15-20mins)
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:30:28 EDT