SVM RAID 10 file system problems

From: Pawel Branski (pawel.branski@foreseeresults.com)
Date: Tue Dec 21 2004 - 11:11:07 EST


Hi,

I have a system with multiple file system created under SVM. The server
is connected to D1000 disk array. I had a short power failure (over 20
seconds). One power supply on D1000 is connected to clean power, second
power supply to dirty power.
D34 / D33 mirror is giving me Needs maintenance / Last Erred messages.
I was able to resolve the problems with the internal disks mirror drives
but the RAID 10 can not too good info on SUN website.
What is the best approach to resolve the mirror problems?

I will summarize. Thank you, Pawel

SunOS xxxxxxx 5.9 Generic_117171-08 sun4u sparc SUNW,Ultra-80
Disk array D1000 connected with 12 drives.

d34: Mirror
    Submirror 0: d14
      State: Needs maintenance
    Submirror 1: d24
      State: Needs maintenance
    Pass: 1
    Read option: roundrobin (default)
    Write option: parallel (default)
    Size: 284482719 blocks (135 GB)

d14: Submirror of d34
    State: Needs maintenance
    Invoke: metareplace d34 c4t3d0s3 <new device>
    Size: 284482719 blocks (135 GB)
    Stripe 0: (interlace: 32 blocks)
        Device Start Block Dbase State Reloc Hot Spare
        c4t0d0s3 0 No Last Erred Yes
        c4t1d0s3 2889 No Last Erred Yes
        c4t2d0s3 2889 No Maintenance Yes
        c4t3d0s3 2889 No Maintenance Yes

d24: Submirror of d34
    State: Needs maintenance
    Invoke: metareplace d34 c4t5d0s3 <new device>
    Size: 284482719 blocks (135 GB)
    Stripe 0: (interlace: 32 blocks)
        Device Start Block Dbase State Reloc Hot Spare
        c4t4d0s3 0 No Maintenance Yes
        c4t5d0s3 2889 No Maintenance Yes
        c4t8d0s3 2889 No Last Erred Yes
        c4t9d0s3 2889 No Last Erred Yes

d33: Mirror
    Submirror 0: d13
      State: Needs maintenance
    Submirror 1: d23
      State: Needs maintenance
    Pass: 1
    Read option: roundrobin (default)
    Write option: parallel (default)
    Size: 70717696 blocks (33 GB)

d13: Submirror of d33
    State: Needs maintenance
    Invoke: metareplace d33 c4t11d0s3 <new device>
    Size: 70717696 blocks (33 GB)
    Stripe 0: (interlace: 32 blocks)
        Device Start Block Dbase State Reloc Hot Spare
        c4t10d0s3 0 No Last Erred Yes
        c4t11d0s3 4712 No Maintenance Yes

d23: Submirror of d33
    State: Needs maintenance
    Invoke: after replacing "Maintenance" components:
                metareplace d33 c4t13d0s3 <new device>
    Size: 70717696 blocks (33 GB)
    Stripe 0: (interlace: 32 blocks)
        Device Start Block Dbase State Reloc Hot Spare
        c4t12d0s3 0 No Last Erred Yes
        c4t13d0s3 4712 No Last Erred Yes

<snap>

Device Relocation Information:
Device Reloc Device ID
c4t4d0 Yes id1,sd@w5005076507cbd864
c4t5d0 Yes id1,sd@w5005076507cba0b6
c4t8d0 Yes id1,sd@SSEAGATE_ST336704LSUN36G_3CD0K25E00007110JEQA
c4t9d0 Yes id1,sd@SFUJITSU_MAN3367M_SUN36G_01X71449____
c4t0d0 Yes id1,sd@w5005076507c937f9
c4t1d0 Yes id1,sd@SFUJITSU_MAJ3364M_SUN36G_01M07649____
c4t2d0 Yes id1,sd@w5005076507c937ef
c4t3d0 Yes id1,sd@w5005076507c93c43
c4t10d0 Yes id1,sd@SSEAGATE_ST318203LSUN18G_LRC7314000001032001V
c4t11d0 Yes id1,sd@SSEAGATE_ST318203LSUN18G_LRC7662400001031H33E
c0t1d0 Yes id1,sd@SSEAGATE_ST318203LSUN18G_LRC77603000070301JNH
c0t0d0 Yes id1,sd@SSEAGATE_ST318203LSUN18G_LRC8033300006032H1M9
c4t12d0 Yes id1,sd@SSEAGATE_ST318203LSUN18G_LRC767090000W0300SSU
c4t13d0 Yes id1,sd@SSEAGATE_ST318203LSUN18G_LRC6476400001031H1FD

-----Original Message-----
From: sunmanagers-bounces@sunmanagers.org
[mailto:sunmanagers-bounces@sunmanagers.org] On Behalf Of
rbhasin@hssworld.com
Sent: Tuesday, December 21, 2004 3:07 AM
To: sunmanagers@sunmanagers.org
Subject: Offtopic: Storage System Comparison

Hi,

Firstly sorry for this offtopic question.

I am in a process of evaluating different storage system for setting up
our enterprise SAN and would like to have your feedback and would like
you
to share your experience on the same. The Storage systems we are looking

in for are namely EMC's CX700 / DMX 1000 or HDS Thunder 9585V or USP100
(equivalent to HP XP12000 series of boxes). I would request you to share

your opinions and experiences about the technology and the support that
these vendor offer.

Thanx in Advance.

Regds,
- Rajan

***************** HSS-Unclassified *************

"Please note: The email domain of Hughes Software Systems Ltd. has
been changed to "hssworld.com" from hss.hns.com"

"DISCLAIMER: This message is proprietary to Hughes Software Systems
Limited (HSS) and is intended solely for the use of the individual
to whom it is addressed. It may contain privileged or confidential
information and should not be circulated or used for any purpose
other than for what it is intended. If you have received this
message in error, please notify the originator immediately. If you
are not the intended recipient, you are notified that you are
strictly prohibited from using, copying, altering, or disclosing
the contents of this message. HSS accepts no responsibility for
loss or damage arising from the use of the information transmitted
by this email including damage from virus."
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:29:54 EDT