Help with memory configuration V880

From: Rebstock, Roland (Roland.Rebstock@usi.net)
Date: Fri Dec 03 2004 - 16:41:00 EST


All, can someone tell me about the memory configuration in this server
output. I cant take the server down to crack the case and Im interested
in if this server has 128's or 256's. I have downloaded the SUN manual
and have found out that there are 3 CPU boards with 16 Slots per board
and at least 8 bank slots are populated on each board. Can someone
further explain? We had a some ram go bad and it was removed but I
never saw what they pulled out. The server should have 12GB of Ram. Im
guessing the server has 128 Dimms installed on all 4 banks and some are
bad possibly on board B bank 1 & 3?

Thanks in Advanced,
Roland Rebstock

System Configuration: Sun Microsystems sun4u Sun Fire 880
System clock frequency: 150 MHz
Memory size: 11264 Megabytes

========================= CPUs
===============================================

           Run E$ CPU CPU
Brd CPU MHz MB Impl. Mask
--- ----- ---- ---- ------- ----
 A 0 750 8.0 US-III 5.4
 B 1 750 8.0 US-III 5.4
 A 2 750 8.0 US-III 5.4
 B 3 750 8.0 US-III 5.4
 C 4 750 8.0 US-III 5.4
 C 6 750 8.0 US-III 5.4

========================= Memory Configuration
===============================

           Logical Logical Logical
      MC Bank Bank Bank DIMM Interleave
Interleaved
 Brd ID num size Status Size Factor with
---- --- ---- ------ ----------- ------ ----------
-----------
  A 0 0 512MB no_status 256MB 8-way 0
  A 0 1 512MB no_status 256MB 8-way 0
  A 0 2 512MB no_status 256MB 8-way 0
  A 0 3 512MB no_status 256MB 8-way 0
  B 1 0 512MB no_status 256MB 4-way 1
  B 1 1 512MB no_status 256MB 2-way 2
  B 1 2 512MB no_status 256MB 4-way 1
  B 1 3 512MB no_status 256MB 2-way 2
  A 2 0 512MB no_status 256MB 8-way 0
  A 2 1 512MB no_status 256MB 8-way 0
  A 2 2 512MB no_status 256MB 8-way 0
  A 2 3 512MB no_status 256MB 8-way 0
  B 3 0 512MB no_status 256MB 4-way 1
  B 3 2 512MB no_status 256MB 4-way 1
  C 4 0 512MB no_status 256MB 8-way 3
  C 4 1 512MB no_status 256MB 8-way 3
  C 4 2 512MB no_status 256MB 8-way 3
  C 4 3 512MB no_status 256MB 8-way 3
  C 6 0 512MB no_status 256MB 8-way 3
  C 6 1 512MB no_status 256MB 8-way 3
  C 6 2 512MB no_status 256MB 8-way 3
  C 6 3 512MB no_status 256MB 8-way 3

========================= IO Cards =========================

" Confidentiality Notice and Disclaimer: This e-mail transmission may
contain confidential and/or proprietary information of USi that is
intended only for the individual or entity named in the e-mail address.
If you are not the intended recipient, you are hereby notified that any
disclosure, copying, distribution, or reliance upon the contents of this
e-mail is strictly prohibited. If you have received this e-mail
transmission in error, please reply to the sender, so that USi can
arrange for proper delivery, and then please delete the message from
your inbox. Thank you. "
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:29:50 EDT