From: Langdon, Nick (nick_langdon@csgsystems.com)
Date: Mon Nov 29 2004 - 06:22:44 EST
Hello all,
I'm getting the following output from metastat d21
d21: Mirror
Submirror 0: d22
State: Needs maintenance
Submirror 1: d23
State: Needs maintenance
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 25168392 blocks (12 GB)
d22: Submirror of d21
State: Unavailable
Size: 25168392 blocks (12 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t8d0s0 0 No - Yes
d23: Submirror of d21
State: Needs maintenance
Invoke: after replacing "Maintenance" components:
metareplace d21 c1t9d0s0 <new device>
Size: 25168392 blocks (12 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t9d0s0 0 No Last Erred Yes
Device Relocation Information:
Device Reloc Device ID
c1t9d0 Yes id1,sd@SSEAGATE_ST136403LC______LT25999700007036MDQD
I know that one of my disks has died but from this output it looks like
both disks have died, is this correct?
If its just one disk that has died what is the best way to remedy this?
Cheers
Nick