Problem with Sun Qlogic HBA and Brocade 12000

From: Cummings, Kyle (kyle.cummings@xmradio.com)
Date: Thu Jul 22 2004 - 09:05:55 EDT


We have a Sun 6800 with two domains. Each domain is running Solaris 8 with
Sun branded Qlogic Dual Port HBA cards.

Both Solaris systems have the same patches and are running Sun SAN 4.3 with
MPXIO on and auto-failback enabled.

SunOS xxxxxxxx 5.8 Generic_117350-04 sun4u sparc SUNW,Sun-Fire

Last Sunday we migrated from Brocade 2802 1GB switches to Brocade 12000 2GB
switches. After migration we began getting the following errors:

Jul 22 08:23:50 xxxxxxxx scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci
(scsi_vhci0):
Jul 22 08:23:50 xxxxxxxx
/scsi_vhci/ssd@g500060e80000000000007e1500000100 (ssd503): Command Timeout
on path /ssm@0,0/pci@1c,600000/SUNW,qlc@1,1/fp@0,0 (fp3)
Jul 22 08:23:50 xxxxxxxx scsi: [ID 243001 kern.warning] WARNING:
/scsi_vhci/ssd@g500060e80000000000007e1500000100 (ssd503):
Jul 22 08:23:50 xxxxxxxx SCSI transport failed: reason 'timeout':
retrying command

Jul 22 06:48:59 xxxxxxxx fp: [ID 517869 kern.info] NOTICE: fp(1): PLOGI to
10500 failed state=Timeout, reason=Hardware Error
Jul 22 06:49:03 xxxxxxxx fp: [ID 517869 kern.info] NOTICE: fp(1): PLOGI to
20500 failed state=Timeout, reason=Hardware Error
Jul 22 06:49:08 xxxxxxxx fp: [ID 517869 kern.info] NOTICE: fp(3): PLOGI to
10500 failed state=Timeout, reason=Hardware Error
Jul 22 06:49:12 xxxxxxxx fp: [ID 517869 kern.info] NOTICE: fp(3): PLOGI to
20500 failed state=Timeout, reason=Hardware Error

Has anyone seen this before?

Kyle Cummings
XM Satellite Radio, Inc.
Principal UNIX Engineer
EIT Infrastructure Group
(202) 380-4182

"I'd take the awe of understanding over the awe of ignorance any day."
-Douglas Adams
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers