help! picld error - is it a hardware issue?

From: ktn (ktn@dodo.com.au)
Date: Thu Jun 10 2004 - 19:55:06 EDT


Dear managers, need your prompt help!

I've been getting these errors in /var/adm/messages constantly since a
reboot a machine, a Sunfire v880 running Solaris 9 Generic_112233-12 (due to
a power failure by the way) --

...
Jun 11 03:12:12 serv picld[93]: [ID 710302 daemon.error] I/O error
Jun 11 03:12:13 serv picld[93]: [ID 478985 daemon.error] ERROR running
psvc_fan_fault_check_policy_0 on CPU1_PRIM_FAN (249
9992)
Jun 11 03:12:13 serv picld[93]: [ID 710302 daemon.error] I/O error
Jun 11 03:12:15 serv picld[93]: [ID 478985 daemon.error] ERROR running
psvc_fan_fault_check_policy_0 on IO_BRIDGE_PRIM_FAN
(2500216)
Jun 11 03:12:15 serv picld[93]: [ID 710302 daemon.error] I/O error
Jun 11 03:12:48 serv picld[93]: [ID 478985 daemon.error] ERROR running
psvc_fan_fault_check_policy_0 on CPU0_PRIM_FAN (249
9960)
Jun 11 03:12:48 serv picld[93]: [ID 710302 daemon.error] I/O error
Jun 11 03:12:49 serv picld[93]: [ID 478985 daemon.error] ERROR running
psvc_fan_fault_check_policy_0 on CPU1_PRIM_FAN (249
9992)
Jun 11 03:12:49 serv picld[93]: [ID 710302 daemon.error] I/O error
Jun 11 03:12:51 serv picld[93]: [ID 478985 daemon.error] ERROR running
psvc_fan_fault_check_policy_0 on IO_BRIDGE_PRIM_FAN
(2500216)
...

In the logs during the reboot, the "PS2 Device unplugged" is the last error
picld gives...could this be a cause of the problem? --
...
May 30 20:37:57 serv eri: [ID 517527 kern.info] SUNW,eri0 : 100 Mbps full
duplex link up
May 30 20:38:00 serv last message repeated 1 time
May 30 20:38:02 serv pseudo: [ID 129642 kern.info] pseudo-device: devinfo0
May 30 20:38:02 serv genunix: [ID 936769 kern.info] devinfo0 is
/pseudo/devinfo@0
May 30 20:42:23 serv picld[93]: [ID 293134 daemon.error] Device PS2
unplugged
May 30 20:42:50 serv fsck[164]: [ID 293258 user.error] libsldap: Status: 2
Mesg: Unable to load configuration '/var/ldap/
ldap_client_file' ('').
May 30 20:42:50 serv last message repeated 3 times
May 30 20:42:50 serv picld[93]: [ID 478985 daemon.error] ERROR running
psvc_fan_fault_check_policy_0 on CPU0_PRIM_FAN (249
9960)
May 30 20:42:50 serv picld[93]: [ID 875627 daemon.error] No such file or
directory
May 30 20:42:51 serv fsck[164]: [ID 293258 user.error] libsldap: Status: 2
Mesg: Unable to load configuration '/var/ldap/
ldap_client_file' ('').
May 30 20:42:51 serv last message repeated 5 times
May 30 20:42:52 serv picld[93]: [ID 478985 daemon.error] ERROR running
psvc_fan_fault_check_policy_0 on CPU1_PRIM_FAN (249
9992)
May 30 20:42:52 serv picld[93]: [ID 875627 daemon.error] No such file or
directory
May 30 20:42:53 serv fsck[164]: [ID 293258 user.error] libsldap: Status: 2
Mesg: Unable to load configuration '/var/ldap/
ldap_client_file' ('').
May 30 20:42:53 serv last message repeated 2 times
...

Running prtdiag shows the following, and the "no memory" part is giving me a
heart attack. Could this just be (from the logs above), an incomplete boot?
I am thinking of rebooting the machine and seeing if it will be the same, or
do you think it's something failing for sure? Many thanks in advance for
reading. Will summarise.

>prtdiag -v
System Configuration: Sun Microsystems sun4u Sun Fire 880
System clock frequency: 150 MHz
Memory size: 8192 Megabytes

========================= CPUs
===============================================

Run E$ CPU CPU
Brd CPU MHz MB Impl. Mask
--- --- ---- ---- ------- ----
A 0 750 8.0 US-III 5.4
B 1 750 8.0 US-III 5.4
A 2 750 8.0 US-III 5.4
B 3 750 8.0 US-III 5.4

========================= Memory Configuration
===============================

Logical Logical Logical
MC Bank Bank Bank DIMM Interleave Interleaved
Brd ID num size Status Size Factor with
---- --- ---- ------ ----------- ------ ---------- -----------
Cannot find any memory bank/segment info.

========================= IO Cards =========================

Bus Max
IO Port Bus Freq Bus Dev,
Brd Type ID Side Slot MHz Freq Func State Name
   Model
---- ---- ---- ---- ---- ---- ---- ---- -----
-------------------------------- ----------------------
I/O PCI 9 A 8 33 66 1,0 ok SUNW,m64B
   SUNW,370-4362

No failures found in System
===========================

========================= Environmental Status =========================

System Temperatures (Celsius):
-------------------------------
Device Temperature Status
---------------------------------------
CPU0 68 OK
CPU1 73 OK
CPU2 59 OK
CPU3 61 OK
MB 31 OK
IOB 26 OK
DBP0 28 OK

=================================

Front Status Panel:
-------------------
Keyswitch position: NORMAL

System LED Status:
GEN FAULT REMOVE
[OFF] [OFF]

DISK FAULT POWER FAULT
[OFF] [OFF]

LEFT THERMAL FAULT RIGHT THERMAL FAULT
[OFF] [OFF]

LEFT DOOR RIGHT DOOR
[OFF] [OFF]

=================================

Disk Status:
Presence Fault LED Remove LED
DISK 0: [PRESENT] [OFF] [OFF]
DISK 1: [PRESENT] [OFF] [OFF]
DISK 2: [PRESENT] [OFF] [OFF]
DISK 3: [PRESENT] [OFF] [OFF]
DISK 4: [PRESENT] [OFF] [OFF]
DISK 5: [PRESENT] [OFF] [OFF]
DISK 6: [ EMPTY]
DISK 7: [ EMPTY]
DISK 8: [ EMPTY]
DISK 9: [ EMPTY]
DISK 10: [ EMPTY]
DISK 11: [ EMPTY]

=================================

Fan Bank :
----------

Bank Speed Status Fan State
( RPMS )
---- -------- --------- ---------
CPU0_PRIM_FAN 1298089537 [ENABLED] OK
CPU1_PRIM_FAN 1298089537 [ENABLED] OK
CPU0_SEC_FAN 0 [DISABLED] OK
CPU1_SEC_FAN 0 [DISABLED] OK
IO0_PRIM_FAN 4000 [ENABLED] OK
IO1_PRIM_FAN 3947 [ENABLED] OK
IO0_SEC_FAN 0 [DISABLED] OK
IO1_SEC_FAN 0 [DISABLED] OK
IO_BRIDGE_PRIM_FANfailed in picl_get_propval_by_name for fan speed
General system failure
Power Supplies:
---------------

Supply Status Fan Fail Temp Fail CS Fail 3.3V 5V 12V 48V
------ ------------ -------- --------- ------- ---- -- --- ---
PS0 GOOD 9 4 3 5
PS1 GOOD 9 3 3 5
PS2 UNPLUGGED

========================= HW Revisions
=======================================

System PROM revisions:
----------------------
OBP 4.5.6 2002/01/04 12:30

IO ASIC revisions:
------------------
Port
Brd Model ID Status Version
---- --------------- ---- ------ -------
IB-1 unknown 8 ok 4
IB-1 unknown 9 ok 4

________________________________________________

Message sent using Dodo
Internet Webmail Server
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:28:50 EDT