UPDATE: Cold swap of disks do not fire up.

From: Jack Matthews (jmatthews@t-graphic.com)
Date: Mon May 03 2004 - 14:40:30 EDT


I have the following additional information.
They are sun seagate ST39204LC. One says it did not power up at boot up one
says it has a corrupt lable and the last one gives no indication of issues
until you run format then lots of bad label messages.
When I go to format and partition and label I get the following feedback
from console;

-----Original Message-----
From: sunmanagers-bounces@sunmanagers.org
[mailto:sunmanagers-bounces@sunmanagers.org]On Behalf Of Jack Matthews
Sent: Monday, May 03, 2004 9:58 AM
To: sunmanagers@sunmanagers.org
Subject: Cold swap of disks do not fire up.

I have installed three new 9.0GB Hard drives into an E450 SUN Server. These
are extra disks and not the boot disks.
However, after doing even a boot -r they are not able to be formatted. each
time I try to format them console reports they are missing lables or are not
ready. any ideas on this one?

Thanks,

Jack
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Sun Microsystems Inc. SunOS 5.8 Generic February 2000
You have mail.
#
May 3 11:59:06 bohr scsi: WARNING: /pci@1f,4000/scsi@3/sd@2,0 (sd2):
May 3
11:59:06 bohr Error for Command: load/start/stop Error Level:
Retryable
May 3 11:59:06 bohr scsi: Requested Block: 0
Error Block: 0
May 3 11:59:06 bohr scsi: Vendor: SEAGATE
Serial Number:
May 3 11:59:06 bohr scsi: Sense Key: Not
Ready
May 3 11:59:06 bohr scsi: ASC: 0x4 (LUN not ready), ASCQ: 0x0,
FRU: 0x2
May 3 11:59:11 bohr scsi: WARNING: /pci@1f,4000/scsi@3/sd@2,0 (sd2):
May 3 11:59:11 bohr Error for Command: load/start/stop Error
Level: Retryable
May 3 11:59:11 bohr scsi: Requested Block: 0
Error Block: 0
May 3 11:59:11 bohr scsi: Vendor: SEAGATE
Serial Number:
May 3 11:59:11 bohr scsi: Sense Key: Not
Ready
May 3 11:59:11 bohr scsi: ASC: 0x4 (LUN not ready), ASCQ: 0x0,
FRU: 0x2
May 3 11:59:16 bohr scsi: WARNING: /pci@1f,4000/scsi@3/sd@2,0 (sd2):
May 3 11:59:16 bohr Error for Command: load/start/stop Error
Level: Retryable
May 3 11:59:16 bohr scsi: Requested Block: 0
Error Block: 0
May 3 11:59:16 bohr scsi: Vendor: SEAGATE
Serial Number:
May 3 11:59:16 bohr scsi: Sense Key: Not
Ready
May 3 11:59:16 bohr scsi: ASC: 0x4 (LUN not ready), ASCQ: 0x0,
FRU: 0x2
May 3 11:59:21 bohr scsi: WARNING: /pci@1f,4000/scsi@3/sd@2,0 (sd2):
May 3 11:59:21 bohr Error for Command: load/start/stop Error
Level: Retryable
May 3 11:59:21 bohr scsi: Requested Block: 0
Error Block: 0
May 3 11:59:21 bohr scsi: Vendor: SEAGATE
Serial Number:
May 3 11:59:21 bohr scsi: Sense Key: Not
Ready
May 3 11:59:21 bohr scsi: ASC: 0x4 (LUN not ready), ASCQ: 0x0,
FRU: 0x2
May 3 11:59:26 bohr scsi: WARNING: /pci@1f,4000/scsi@3/sd@2,0 (sd2):
May 3 11:59:26 bohr Error for Command: load/start/stop Error
Level: Retryable
May 3 11:59:26 bohr scsi: Requested Block: 0
Error Block: 0
May 3 11:59:26 bohr scsi: Vendor: SEAGATE
Serial Number:
May 3 11:59:26 bohr scsi: Sense Key: Not
Ready
May 3 11:59:26 bohr scsi: ASC: 0x4 (LUN not ready), ASCQ: 0x0,
FRU: 0x2
May 3 11:59:31 bohr scsi: WARNING: /pci@1f,4000/scsi@3/sd@2,0 (sd2):
May 3 11:59:31 bohr Error for Command: load/start/stop Error
Level: Retryable
May 3 11:59:31 bohr scsi: Requested Block: 0
Error Block: 0
May 3 11:59:31 bohr scsi: Vendor: SEAGATE
Serial Number:
May 3 11:59:31 bohr scsi: Sense Key: Not
Ready
May 3 11:59:31 bohr scsi: ASC: 0x4 (LUN not ready), ASCQ: 0x0,
FRU: 0x2
May 3 11:59:34 bohr scsi: WARNING: /pci@1f,4000/scsi@3/sd@2,0 (sd2):
May 3 11:59:34 bohr offline
May 3 11:59:36 bohr scsi: WARNING:
/pci@1f,4000/scsi@3/sd@2,0 (sd2):
May 3 11:59:36 bohr Error for Command:
load/start/stop Error Level: Retryable
May 3 11:59:36 bohr scsi:
Requested Block: 0 Error Block: 0
May 3 11:59:36 bohr
scsi: Vendor: SEAGATE Serial Number:
May 3 11:59:36 bohr scsi: Sense Key: Not Ready
May 3 11:59:36 bohr
scsi: ASC: 0x4 (LUN not ready), ASCQ: 0x0, FRU: 0x2
May 3 11:59:41 bohr
scsi: WARNING: /pci@1f,4000/scsi@3/sd@2,0 (sd2):
May 3 11:59:41 bohr Error
for Command: load/start/stop Error Level: Retryable
May 3 11:59:41
bohr scsi: Requested Block: 0 Error Block: 0
May
3 11:59:41 bohr scsi: Vendor: SEAGATE Serial
Number:
May 3 11:59:41 bohr scsi: Sense Key: Not Ready
May
3 11:59:41 bohr scsi: ASC: 0x4 (LUN not ready), ASCQ: 0x0, FRU: 0x2
May
3 11:59:44 bohr scsi: WARNING: /pci@1f,4000/scsi@3/sd@3,0 (sd3):
May 3
11:59:44 bohr corrupt label - label checksum failed
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:28:35 EDT