[SUMMARY: E4500 trouble

From: Dirk Boenning (dirk.boenning@ccf.de)
Date: Tue Mar 30 2004 - 09:13:42 EST


Hello,

again as fast as possible.
The winner is:

Alex Madden <Alex.Madden@betfair.com>

--
read about the obp command copy-clock-tod-to-io-boards
--
Dirk Boenning wrote:
> Hello,
> 
> 
> I've just tried to boot up an old E4500 after a couple of weeks powered 
> off and got the following message:
> 
> clockboard TOD does not match tod on any io board
> 
> The system doesn't boot but comes up to the OK prompt. It seems that the 
> I/O Boards not activated and the maintenace led on the clockboard is on.
> 
> Any glue what's going on and how to get this on up again ?
> 
> 
> TIA, Dirk.
> 
> 
-- 