From: Michael Schneider (lists@calispera.com)
Date: Mon Dec 15 2003 - 05:44:33 EST
Hi Managers,
my Problem.. after a cable problem on my system the following status is
shown by metastat. The Disk is now ok (cable problem) but i can4t clear the
fault status ..
d6: Mirror
Submirror 0: d60
State: Needs maintenance
Submirror 1: d70
State: Needs maintenance
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 82803600 blocks
d60: Submirror of d6
State: Needs maintenance
Invoke: metareplace d6 c0t4d0s0 <new device>
Size: 82803600 blocks
Stripe 0:
Device Start Block Dbase State Hot Spare
c0t4d0s0 0 No Maintenance
d70: Submirror of d6
State: Needs maintenance
Invoke: after replacing "Maintenance" components:
metareplace d6 c0t5d0s0 <new device>
Size: 82803600 blocks
Stripe 0:
Device Start Block Dbase State Hot Spare
c0t5d0s0 0 No Last Erred
-- Michael Schneider _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagers
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:27:41 EDT