From: Steve Mickeler (steve@warning.ca)
Date: Tue Oct 07 2003 - 21:32:12 EDT
Having run out of resources I'm hoping the list can lend me a hand.
I'm in the middle of setting up dedicated SAN for backups with 2 Brocade
2800's and for the life of me I cannot get the 2 switches to join into a
single fabric with either 1, 2 or 3 ISL links between them.
What seems to be happening is that switch2 doesnt seem to be entering
the subordinate switchRole and picking up the zone info from switch 1 and
then its segments the fabric instead of creating one between the 2
switches.
The error I keep getting is:
WARNING FABRIC-SEGMENTED, 3, port 13, disabled E_Port
switch1 = domain id: 1 - Only switch with configed zone info
switch2 = domain id: 2 - no zone info
Here's the switch info for both switches.
admin> version
Kernel: 5.4
Fabric OS: v2.6.1b
Made on: Thu Aug 14 17:29:18 PDT 2003
Flash: Thu Aug 14 17:29:57 PDT 2003
BootProm: Thu Jun 17 15:20:39 PDT 1999
switchShow on switch 1 shows
switchRole: Principal
switchDomain: 1
Zoning: ON (backup_san)
port 13: id Online E-Port (segmented,disabled E_Port)
switchShow on switch 2 shows:
switchRole: Principal
switchDomain: 2
Zoning: OFF
port 13: id Online E-Port (segmented,disabled E_Port)
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers