L60 Tape Library

From: willief (willief@base-2.com)
Date: Mon Sep 29 2003 - 11:03:15 EDT


Hello,

I have an L60 library that had a tape get stuck in a drive during backup.

I powered down the L60

I had to remove the drive and manually remove the tape. I reinstalled the
drive.

Powered the L60 back on.

It gave the following error:
                
                Timed out on "Command sent to transport controller"
                Hard Error
                Code 12 Qualifier 25 sequence 144, 145, 106, 101, 52
                Suggestion: Make sure cartridges are fully seated
                in their slots.

I did run re-calibrate and it then got:

                Timed out on "Command sent to transport controller"
                Hard Error
                Code 0 Qualifier 86 sequence 144, 145, 106, 101, 52
                Suggestion: Run recalibrate library

        It gave this error before anything physically moved inside,
        ie: motors, tapes, robotics, etc.
        
I ran "Recalibrate Library". Gets the same error.

I've removed all magazines, all drives, reseated all cards. It still gives
the same error code.

Is there another reset similar to "Set-defaults" at the OK prompt, that
would clear any possible config issues stuck in memory?

Any other suggestions?

Thanks

Willie

/-------------------------------------------------------------------\
| Willie Flint willief@base-2.com |
| Base 2 Technologies, Inc. 253.437.1182 |
| 22342 68th Avenue South 253.437.1183 Fax |
| Kent, WA. 98032 www.base-2.com |
|-------------------------------------------------------------------|
| Advanced Computing and Electronics * Corp/Mil * Sales * Repair |
\-------------------------------------------------------------------/
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers