E3500 PCM problem no green diag led

From: Richard.Skelton@infineon.com
Date: Tue Jul 08 2003 - 09:06:12 EDT


Hi,
One of my E3500 PCM has no diag leds. All the others have one green led on.
Each system has three PCM's and I have five systems.
prtdiag show the same on all five systems:-
rskelton: prtdiag -v
System Configuration: Sun Microsystems sun4u 5-slot Sun Enterprise E3500
System clock frequency: 100 MHz
Memory size: 8192Mb

========================= CPUs =========================

                    Run Ecache CPU CPU
Brd CPU Module MHz MB Impl. Mask
--- --- ------- ----- ------ ------ ----
 3 6 0 400 8.0 US-II 10.0
 3 7 1 400 8.0 US-II 10.0
 5 10 0 400 4.0 US-II 9.0
 5 11 1 400 4.0 US-II 10.0
 7 14 0 400 4.0 US-II 9.0
 7 15 1 400 4.0 US-II 9.0
 9 18 0 400 8.0 US-II 10.0
 9 19 1 400 8.0 US-II 10.0

========================= Memory =========================

                                              Intrlv. Intrlv.
Brd Bank MB Status Condition Speed Factor With
--- ----- ---- ------- ---------- ----- ------- -------
 3 0 1024 Active OK 60ns 8-way A
 3 1 1024 Active OK 60ns 8-way A
 5 0 1024 Active OK 60ns 8-way A
 5 1 1024 Active OK 60ns 8-way A
 7 0 1024 Active OK 60ns 8-way A
 7 1 1024 Active OK 60ns 8-way A
 9 0 1024 Active OK 60ns 8-way A
 9 1 1024 Active OK 60ns 8-way A

========================= IO Cards =========================

     Bus Freq
Brd Type MHz Slot Name Model
--- ---- ---- ---------- --------------------------------
----------------------
 1 SBus 25 0 network SUNW,sbus-gem

 1 SBus 25 1 QLGC,isp/sd (block) QLGC,ISP1000U

 1 SBus 25 3 SUNW,hme

 1 SBus 25 3 SUNW,fas/sd (block)

 1 SBus 25 13 SUNW,socal/sf (scsi-3) 501-3060

No failures found in System
===========================

No System Faults found
======================

Most recent AC Power Failure:
=============================
Mon Jul 5 16:42:50 1999

========================= Environmental Status =========================
Keyswitch position is in Normal Mode
System Power Status: Redundant
System LED Status: GREEN YELLOW GREEN
Normal ON OFF BLINKING

Fans:
-----
Unit Status
---- ------
Disk OK

System Temperatures (Celsius):
------------------------------
Brd State Current Min Max Trend
--- ------- ------- --- --- -----
 1 OK 39 37 39 stable
 3 OK 33 28 35 stable
 5 OK 42 37 43 stable
 7 OK 38 34 40 stable
 9 OK 40 35 41 stable
CLK OK 34 32 34 stable

Power Supplies:
---------------
Supply Status
--------- ------
1 OK
3 OK
5 OK
PPS OK
    System 3.3v OK
    System 5.0v OK
    Peripheral 5.0v OK
    Peripheral 12v OK
    Auxilary 5.0v OK
    Peripheral 5.0v precharge OK
    Peripheral 12v precharge OK
    System 3.3v precharge OK
    System 5.0v precharge OK
AC Power OK

========================= HW Revisions =========================

ASIC Revisions:
---------------
Brd FHC AC SBus0 SBus1 PCI0 PCI1 FEPS Board Type Attributes
--- --- -- ----- ----- ---- ---- ---- ---------- ----------
 1 1 5 1 1 22 Dual-SBus-SOC+ 100MHz Capable
 3 1 5 CPU 100MHz Capable
 5 1 5 CPU 100MHz Capable
 7 1 5 CPU 100MHz Capable
 9 1 5 CPU 100MHz Capable

System Board PROM revisions:
----------------------------
Board 1: FCODE 1.8.30 2002/10/25 14:02 iPOST 3.4.30 2002/10/25 14:03
Board 3: OBP 3.2.30 2002/10/25 14:03 POST 3.9.30 2002/10/25 14:04
Board 5: OBP 3.2.30 2002/10/25 14:03 POST 3.9.30 2002/10/25 14:04
Board 7: OBP 3.2.30 2002/10/25 14:03 POST 3.9.30 2002/10/25 14:04
Board 9: OBP 3.2.30 2002/10/25 14:03 POST 3.9.30 2002/10/25 14:04
rskelton:

Cheers
Richard.
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:26:43 EDT