SUMMARY: PGF: 3510 - pad kontrolera

From: przemolicc@poczta.fm
Date: Fri May 09 2003 - 07:03:37 EDT


I am sorry for the following message !
Very sorry !

przemol

> On Fri, May 09, 2003 at 12:39:42PM +0200, przemolicc@poczta.fm wrote:
> > Dzieq dobry,
> >
> > w w/w macierzy (FC) pad3 kontroler. Poni?ej komunikaty:
> > bash-2.05# sccli
> > sccli: selected device /dev/rdsk/c4t600C0FF00000000000164F463D6E9D00d0s2 [SUN StorEdge 3510 SN#00164F]
> > sccli> show events
> >
> > Thu May 8 13:06:27 2003
> > [0181] #1: StorEdge Array SN#0 Controller NOTICE: controller initialization completed
> >
> > Thu May 8 13:06:33 2003
> > [0181] #2: StorEdge Array SN#0 Controller NOTICE: controller initialization completed
> >
> > Fri May 9 11:52:24 2003
> > [0111] #3: StorEdge Array SN#0 Controller ALERT: redundant controller failure detected
> >
> > Kolor i miganie diod na macierzy z ty3u potwierdzaj1 te objawy.
> >
> > Pozdrawiam
> >
> > Przemek B1k
> > PGF S.A.
> >

----- End forwarded message -----
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 23:26:23 EDT