Re: VINA eLink-208

From: Paul Melson (pmelson@gmail.com)
Date: Fri Dec 22 2006 - 21:58:00 EST


On 12/22/06, Dave <dave.j.moore+seclists@gmail.com> wrote:
> I attempted to telnet into the host and received 'Unable to connect to
> remote host: Invalid Argument' immediately.

Try netcat. 'Invalid Argument' is an error message that is often
triggered pre-connection. Without the exact syntax and environment
variables (i.e. $TERM), it's impossible to pinpoint the root cause.

> VINA eLink-208 with ePort - 8 (5.1.10)

VINA was acquired by Larscom and Larscom has since been acquired by
Verilink. The documentation is online here:

http://verilink.custhelp.com/cgi-bin/verilink.cfg/php/enduser/std_adp.php?p_faqid=737&p_created=1118169520&p_sid=JQxoqPpi&p_lva=&p_sp=cF9zcmNoPTEmcF9zb3J0X2J5PWRmbHQmcF9ncmlkc29ydD0mcF9yb3dfY250PTImcF9wcm9kcz0xOSwzMiZwX2NhdHM9MTY2JnBfcHY9Mi4zMiZwX2N2PTEuMTY2OzIudTAmcF9zZWFyY2hfdHlwZT1hbnN3ZXJzLnNlYXJjaF9ubCZwX3NjZl9zdGF0dXM9JnBfcGFnZT0x&p_li=&p_topview=1

> Too many incorrect logins...login disabled

Oh, that's not good. You may want to contact your client immediately
to tell them about this little SNAFU. I see a factory reset in this
thing's future.

PaulM



This archive was generated by hypermail 2.1.7 : Sat Apr 12 2008 - 10:57:30 EDT