CURRENT MONITOR DATA: Event Time..........: Thu Nov 29 04:10:17 2007 Severity............: CRITICAL Monitor.............: disk_em Event #.............: 100057 System..............: squonk Summary: Disk at hardware path 10/12.9.0 : Hardware failure Description of Error: The device was unsuccessful in processing the current I/O request due to an internal target failure. The request may have been processed in a way which could cause damage to or loss of data. Probable Cause / Recommended Action: The device has experienced a hardware failure. Contact your HP support representative to have the device checked. Additional Event Data: System IP Address...: 192.168.2.1 Event Id............: 0x474e81f900000000 Monitor Version.....: B.01.01 Event Class.........: I/O Client Configuration File...........: /var/stm/config/tools/monitor/default_disk_em.clcfg Client Configuration File Version...: A.01.00 Qualification criteria met. Number of events..: 1 Associated OS error log entry id(s): 0x474e81f800000000 Additional System Data: System Model Number.............: 9000/800 OS Version......................: B.11.11 STM Version.....................: A.55.00 EMS Version.....................: A.04.20 Latest information on this event: http://docs.hp.com/hpux/content/hardware/ems/scsi.htm#100057 v-v-v-v-v-v-v-v-v-v-v-v-v D E T A I L S v-v-v-v-v-v-v-v-v-v-v-v-v Component Data: Physical Device Path...: 10/12.9.0 Device Class...........: Disk Inquiry Vendor ID......: IBM Inquiry Product ID.....: DGHS09Y Firmware Version.......: HP08 Serial Number..........: 6816FD1AGA Product/Device Identification Information: Logger ID.........: sdisk Product Identifier: SCSI Disk Product Qualifier.: IBMDGHS09Y SCSI Target ID....: 0x09 SCSI LUN..........: 0x00 I/O Log Event Data: Driver Status Code..................: 0x0000007E Length of Logged Hardware Status....: 36 bytes. Offset to Logged Manager Information: 36 bytes. Length of Logged Manager Information: 34 bytes. Hardware Status: Raw H/W Status: 0x0000: 00 00 00 02 70 00 04 00 00 00 00 18 00 00 00 00 0x0010: 44 00 01 00 00 00 00 00 01 3F 00 00 FF FF FF FF 0x0020: FF FF 00 00 SCSI Status...: CHECK CONDITION (0x02) Indicates that a contingent allegiance condition has occurred. Any error, exception, or abnormal condition that causes sense data to be set will produce the CHECK CONDITION status. SCSI Sense Data: Undecoded Sense Data: 0x0000: 70 00 04 00 00 00 00 18 00 00 00 00 44 00 01 00 0x0010: 00 00 00 00 01 3F 00 00 FF FF FF FF FF FF 00 00 SCSI Sense Data Fields: Error Code : 0x70 Segment Number : 0x00 Bit Fields: Filemark : 0 End-of-Medium : 0 Incorrect Length Indicator : 0 Sense Key : 0x04 Information Field Valid : FALSE Information Field : 0x00000000 Additional Sense Length : 24 Command Specific : 0x00000000 Additional Sense Code : 0x44 Additional Sense Qualifier : 0x00 Field Replaceable Unit : 0x01 Sense Key Specific Data Valid : FALSE Sense Key Specific Data : 0x00 0x00 0x00 Sense Key 0x04, HARDWARE ERROR, indicates that the device detected a nonrecoverable hardware failure (for example, controller failure, device failure, parity error, etc.) while performing the command or during a self test. The combination of Additional Sense Code and Sense Qualifier (0x4400) indicates: Internal target failure. SCSI Command Data Block: Command Data Block Contents: 0x0000: 28 00 00 0F B1 20 00 00 10 00 Command Data Block Fields (10-byte fmt): Command Operation Code...(0x28)..: READ Logical Unit Number..............: 0 DPO Bit..........................: 0 FUA Bit..........................: 0 Relative Address Bit.............: 0 Logical Block Address............: 1028384 (0x000FB120) Transfer Length..................: 16 (0x0010) Manager-Specific Data Fields: Request ID.............: 0x03AEBBE1 Data Residue...........: 0x00000400 CDB status.............: 0x00000002 Sense Status...........: 0x00000000 Bus ID.................: 0x03 Target ID..............: 0x09 LUN ID.................: 0x00 Sense Data Length......: 0x20 Q Tag..................: 0x6F Retry Count............: 14