From: Javier González Arenas [ conatel ] (jgonzalez@conatel.com.uy)
Date: Wed May 11 2005 - 10:58:37 EDT
Hello there,
Thanks for your suggestions about the powerfailing disk, I'll take the
correcting actions in this order:
- check the scsi cables
- replace the disk
- replace the scsi controller
By the way, given the following message, which disk is supposed to be
replaced ?
May 6 17:20:47 parma2 vmunix: LVM: vg[1]: pvnum=3 (dev_t=0x1f000000) is
POWERFAILED
I've got the following disks on my system::
root@parma2:/>ll /dev/dsk/*
brw-r----- 1 bin sys 31 0x000000 Mar 25 1999
/dev/dsk/c0t0d0
brw-r----- 1 bin sys 31 0x005000 Mar 24 1999
/dev/dsk/c0t5d0
brw-r----- 1 bin sys 31 0x006000 Mar 24 1999
/dev/dsk/c0t6d0
brw-r----- 1 bin sys 31 0x008000 Aug 29 2003
/dev/dsk/c0t8d0
brw-r----- 1 bin sys 31 0x013000 Mar 24 1999
/dev/dsk/c1t3d0
brw-r----- 1 bin sys 31 0x014000 Mar 24 1999
/dev/dsk/c1t4d0
brw-r----- 1 bin sys 31 0x015000 Mar 24 1999
/dev/dsk/c1t5d0
brw-r----- 1 bin sys 31 0x016000 Mar 24 1999
/dev/dsk/c1t6d0
brw-r----- 1 bin sys 31 0x026000 Mar 24 2000
/dev/dsk/c2t6d0
brw-r----- 1 bin sys 31 0x032000 Mar 24 1999
/dev/dsk/c3t2d0
Best regards,
javier
----- Original Message -----
From: "Javier González Arenas [ conatel ]" <jgonzalez@conatel.com.uy>
To: "hpux-admin" <hpux-admin@DutchWorks.nl>
Sent: Tuesday, May 10, 2005 5:23 PM
Subject: [HPADM] [hpadm] physical volume powerfailed
> Hello there,
>
> I'm getting sporadically the following error in syslog.log:
>
> May 6 17:20:47 parma2 vmunix: LVM: vg[1]: pvnum=3 (dev_t=0x1f000000) is
> POWERFAILED
> May 6 17:54:46 parma2 vmunix: DIAGNOSTIC SYSTEM WARNING:
> May 6 17:54:46 parma2 vmunix: The diagnostic logging facility has
> started receiving excessive
> May 6 17:54:46 parma2 vmunix: errors from the I/O subsystem. I/O
> error entries will be lost
> May 6 17:54:46 parma2 vmunix: until the cause of the excessive I/O
> logging is corrected.
> May 6 17:54:46 parma2 vmunix: If the diaglogd daemon is not active,
> use the Daemon Startup command
> May 6 17:54:46 parma2 vmunix: in stm to start it.
> May 6 17:54:46 parma2 vmunix: If the diaglogd daemon is active, use
> the logtool utility in stm
> May 6 17:54:46 parma2 vmunix: to determine which I/O subsystem is
> logging excessive errors.
>
>
> The applications hung and only a reboot can make things work again.
>
> Anyone had overcome this issue in the past and wants to give advice.
>
> Thanks again,
> javier
>
-- ---> Please post QUESTIONS and SUMMARIES only!! <--- To subscribe/unsubscribe to this list, contact majordomo@dutchworks.nl Name: hpux-admin@dutchworks.nl Owner: owner-hpux-admin@dutchworks.nl Archives: ftp.dutchworks.nl:/pub/digests/hpux-admin (FTP, browse only) http://www.dutchworks.nl/htbin/hpsysadmin (Web, browse & search)
This archive was generated by hypermail 2.1.7 : Sat Apr 12 2008 - 11:02:47 EDT