As a side note to this, where did you get the batteries? I've got a SSA adapter that needs new batteries but I'm not sure where to begin looking... 6225 IBM SSA 160 SerialRAID Adapter Alan Times New RomanOn 30 May 2003, at 8:58, Darryl Ousterhout wrote: Arial Rounded MT BoldDate sent: Fri, 30 May 2003 08:58:32 -0500 Send reply to: IBM AIX Discussion List < From: Darryl Ousterhout < Subject: Re: SSA Cache battery replacement Originally to: IBM AIX Discussion List < To: aix-l@Princeton.EDU 0000,0000,FF00ArialMat,Times New Roman 0000,0000,FF00ArialThe batteries typically have about 1000 hours of use left in them after the first error is generated in the error report. We had a CE come in and replace all of ours, we had 6 that failed at the exact same time. Afterwards he ran an apparently undocumented (that's what he said) command: ssa_format -l ssa# -b Times New Roman 0000,0000,FF00ArialWhere # is obviously the SSA loop that the FWC resides on. If your sick of seeing errors in the errpt, you can run this anytime to reset the battery timer, just remember it really does need replacement eventually. Times New Roman 0000,0000,FF00ArialRegards,Times New Roman 0000,0000,FF00ArialDarrylTimes New Roman leftTahoma-----Original Message----- From: Gipson, Mat [mailto:Mat.Gipson@AMERICREDIT.COM] Sent: Friday, May 30, 2003 8:18 AM To: aix-l@Princeton.EDU Subject: SSA Cache battery replacement leftArialQuestion for all of you... How do I "reset" a F/W cache battery? I replaced the burned out battery and it still shows the old battery statistics...i.e. battery hours.Times New Roman leftArial Times New Roman leftArialAny help is greatly appreciated!Times New Roman leftArial Times New Roman leftMathew Gipson to:matt.gipson@americredit.com"0000,0000,FF00matt.gipson@americredit.com <23 "I don't have time to be impatient." Alan R. Vidmar Assistant Director of IT Office of Financial Aid University of Colorado Alan.Vidmar@Colorado.EDU (303)492-3598 *** This message printed with 100% recycled electrons ***