From: Lieberg, Patrick (plieberg@EV3.NET)
Date: Wed Jan 14 2004 - 09:45:51 EST


In my previous position, we had a number of 4.3.3, PSSP 3.2 systems on SP and SP2 switches. I do remember seeing these Transient errors on occasion when we would reboot individual nodes or entire frames. I don't think its a serious error, but its been a couple years since I worked on a PSSP system, so you might take my advice with a grain (or maybe a boulder) of salt.

-Patrick Lieberg
Systems Administrator
ev3 Inc.

-----Original Message-----
From: IBM AIX Discussion List [mailto:aix-l@Princeton.EDU]On Behalf Of
Klaus Oberle
Sent: Wednesday, January 14, 2004 8:06 AM
To: aix-l@Princeton.EDU
Subject: Re: Error log entries following SP Switch Efence

Simon,

we're running AIX 4.3.3 / PSSP 3.1.1 at out SP-Nodes. After an Efence,
errpt looks as follows:

IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION
D59DE7C2 0114141504 P H css Switch adapter link outage
C20D6A08 0114141504 I O Worm Node fence request received
C20D6A08 0114141504 I O Worm Node fence request received

Eunfence doesn't produces any errpt entries.

HTH

/klaus

---------------------------------------------------
Klaus Oberle
IT Administration
Linde Material Handling
Aschaffenburg / Germany
klaus.oberle@linde-mh.de
www.linde.com
---------------------------------------------------

                      "Green, Simon"
                      <Simon.Green@EU.A An: aix-l@Princeton.EDU
                      LTRIA.COM> Kopie:
                      Gesendet von: IBM Thema: Error log entries following SP Switch Efence
                      AIX Discussion
                      List
                      <aix-l@Princeton.
                      EDU>

                      14.01.2004 12:21
                      Bitte antworten
                      an IBM AIX
                      Discussion List

We had a switch adapter failure a couple of days ago. (This is the old SP
Switch: not the newer ones, but not the very old HiP Switch.)
Unfortunately, the node - an S7A - is still on AIX 4.3.3 and PSSP 3.2, so
we
didn't have a lot of luck getting assistance from IBM.

I was able to re-start the Worm daemon and Eunfence the node, so the
consensus was that it was a one-off glitch, and just to ignore it for now.

I've been getting the server ready to re-start the application - it's in an
HACMP cluster, so the application is on the standby server at the moment -
and took the opportunity to re-boot it - partly to see what happened to the
switch.

Well, the switch adapter came up as normal. But I noticed an odd error in
the error log from the Efence I issued before rebooting.

EBF464AF 0114102804 P H css Switch adapter link outage
E94651FA 0114102804 T H css Switch adapter transient error
DC85B51D 0114102804 I O Worm Node fence request received
DC85B51D 0114102804 I O Worm Node fence request received

It's the transient error that interests me in particular.

I can't remember if this is normal for the SP Switch. I tried Efence again
for this node and it produces the same results. Unfortunately I don't have
a test system which I can fence, for comparison. None of the other systems
have been Efenced recently, so they don't have any useful entries in their
error logs.

Can anyone tell me if this is a normal sequence of error log entries for a
simple "Efence node" operation?

--
Simon Green
Altria ITSC Europe Ltd
AIX-L Archive at https://new-lists.princeton.edu/listserv/aix-l.html
New to AIX? http://publib-b.boulder.ibm.com/redbooks.nsf/portals/UNIX
N.B. Unsolicited email from vendors will not be appreciated.
Please post all follow-ups to the list.
This e-mail may contain confidential and/or privileged information.
If you are not the intended recipient (or have received this e-mail
in error) please notify the sender immediately and destroy this e-mail.
Any unauthorised copying, disclosure or distribution of the material
in this e-mail is strictly forbidden.
Any views expressed in this message are those of  the  individual
sender,  except  where  the sender specifically states them to be
the views of Linde Material Handling.
Since January 2002 we use the e-mail domain linde-mh.de instead
of linde-fh.de.
This mail has been swept for the presence of computerviruses.
_____________________________________________________________________
Message scanned for viruses
_____________________________________________________________________
This message has been checked for all known viruses


This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:30 EDT