Re: Error log entries following SP Switch Efence

From: Green, Simon (Simon.Green@EU.ALTRIA.COM)
Date: Wed Jan 14 2004 - 08:36:54 EST


My main interest is not - yet - figuring out what this means, but simply if
it's normal when you fence a node.

Here's the detailed error report, anyway.

LABEL: TB3_TRANSIENT_RE
IDENTIFIER: E94651FA

Date/Time: Wed Jan 14 10:28:46
Sequence Number: 166211
Machine Id: XXXXXXXXXXXX
Node Id: XXXXXXXX
Class: H
Type: TEMP
Resource Name: css
Resource Class: NONE
Resource Type: NONE
Location: NONE

Description
Switch adapter transient error

Probable Causes
Loose, disconnected or bad switch cable

User Causes
Switch cable loose or disconnected

        Recommended Actions
        Check / reconnect / replace cable if problem persists

Failure Causes
Switch cable faulty

        Recommended Actions
        Check / reconnect / replace cable if problem persists

Detail Data
DETECTING MODULE
PSSP,TB3recovery.c,1.41,660
ERROR ID
6u5ZFd1SbF/.//LM1H0KZb0...................
REFERENCE CODE
7a12...SbF/./AHM1H0KZb0...................
Interrupt source (ISR or MX CFG3)
TBIC intr

Bus Err (DMA CSR, MX MBA_ER, PCI C/S)
        b8000240

> -----Original Message-----
> From: JOSEPH KREMBLAS [mailto:jkremblas@REDHEARTGIFTS.COM]
> Sent: 14 January 2004 13:20
> To: aix-l@Princeton.EDU
> Subject: Re: Error log entries following SP Switch Efence
>
>
> Can you provide the detailed results from errpt? I'd like to
> see if there
> are any sense error codes for the transient error.



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:30 EDT