From: Patrick B. O'Brien (pobrien@DOIT.NV.GOV)
Date: Wed Nov 12 2003 - 18:31:34 EST
The SSA Service Guide, contains great examples; you then get it from the horse's mouth.
-----Original Message-----
From: Adams Kevin J [mailto:kevin.adams@PHS.COM]
Sent: Wednesday, November 12, 2003 3:21 PM
To: aix-l@Princeton.EDU
Subject: Re: SSA cabling
I always try to use all the connectors by creating loops as follows:
ssa0:b2:j4----j1:b2:ssa1
ssa0:b1:j5----j8:b1:ssa1
ssa0:a2:j16---j13:a2:ssa1
ssa0:a2:j9----j12:a2:ssa1
There has been some debate as to whether you actually get more bandwidth and
thruput this way.
Kevin Adams
PacifiCare Behavioral Health
Principal Systems Analyst
AIX CATE
-----Original Message-----
From: -ray [mailto:ray@OPS.SELU.EDU]
Sent: Wednesday, November 12, 2003 1:59 PM
To: aix-l@Princeton.EDU
Subject: [aix-l] SSA cabling
All,
I'm setting up a new 7133 drawer and need some advice on cabling. Our
current drawer is connected to two adapters. 2 RAID-0 stripes, and an AIX
mirror. Is the correct cabling? It's been running in production like
this for years:
SSA1 7133 SSA2
B2 4 |-- 1 B2
|
B1 5 | 16--| B1
| |
A2 ---- 8 | 13 |--A2
|-------
A1 -- 9 12 A1
| |
---------------
So on the 1st adapter, A2->8, A1->1, 2nd adapter A2->16, A1->9.
For the new drawer, i'd like to do RAID-10 in hardware. It's also connect
to two separate adapters. The first config i did looks like this and
seems to work fine:
1st adapter A2->8, A1->9, 2nd adapter A2->1, A1->16.
But the "Understanding SSA Subsystems" book seems to suggest this cabling
for a "Simple loop with two adapters":
1st adapter A2->8, A1->9, 2nd adapter B2->1, B1>16.
Any advice as to which is more correct?
ray
-- =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-= Ray DeJean http://www.r-a-y.org Systems Engineer Southeastern Louisiana University IBM Certified Specialist AIX Administration, AIX Support =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-= This electronic message transmission, including any attachments, contains information from PacifiCare Health Systems Inc. which may be confidential or privileged. The information is intended to be for the use of the individual or entity named above. If you are not the intended recipient, be aware that any disclosure, copying, distribution or use of the contents of this information is prohibited. If you have received this electronic transmission in error, please notify the sender immediately by a "reply to sender only" message and destroy all electronic and hard copies of the communication, including attachments.
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:21 EDT