Re: SPECIAL NOTICE: Technical Support Bulletin

From: Ken Sedlacek (Ken.Sedlacek@AGILYSYS.COM)
Date: Thu Oct 23 2003 - 17:02:50 EDT


Enviro:

AIX 4.3.3-10

What is the AIX command to restart the cron daemon as it applies to this
Technical Bulletin?

I can't reboot unless there is no other way around this.

TIA.

Ken Sedlacek
AIX/TSM/UNIX Administrator
ken.sedlacek@agilysys.com
Agilysys, Inc. (formerly Kyrus Corp.)

IBM eServer Certified Specialist: pSeries AIX v5 Support
IBM Certified Specialist: RS/6000 SP & PSSP 3
Tivoli Certified Consultant - Tivoli Storage Manager v4.1

Bill Verzal <BVerzal@KOMATSUNA.COM>
Sent by: IBM AIX Discussion List <aix-l@Princeton.EDU>

10/16/2003 01:49 PM

Please respond to
IBM AIX Discussion List <aix-l@Princeton.EDU>

To
aix-l@Princeton.EDU

cc

Subject
SPECIAL NOTICE: Technical Support Bulletin

--------------------------------------------------------

"If everything is coming your way, then you are in the wrong lane"

Bill Verzal
AIX Administrator, Komatsu America
(847) 970-3726 - direct
(847) 970-4184 - fax
----- Forwarded by Bill Verzal/HQ/KAIC on 10/16/2003 12:42 PM -----
|---------+------------------------------->
| | pSeries_TechBulletin|
| | @us.ibm.com |
| | |
| | 10/16/2003 06:40 AM |
| | |
|---------+------------------------------->

>---------------------------------------------------------------------------
----------------------------------------------------|
|
|
| To: bverzal@komatsuna.com
|
| cc:
|
| Subject: SPECIAL NOTICE: Technical Support Bulletin
|

>---------------------------------------------------------------------------
----------------------------------------------------|

(Embedded image moved to file: pic28145.gif)

(Embedded image moved to file: pic23281.gif) (Embedded image
moved to file:
pic16827.gif)

You have received this email because
bverzal@komatsuna.com is subscribed to support bulletins Supported
products
for selected topics. Following are updates for one or
more of the topics you requested. Find end of
support
dates for AIX and
software running on
System clock may become incorrect during daylight AIX
savings time changes.
pSeries support
IBM recommends you take immediate action. Customers
running Visit pSeries
AIX 4.3 or AIX 5.1 need to read ITEM 1. Customers Support for a
wide
running array of
technical
AIX 5.2 need to read both ITEM 1 and ITEM 2. resources.

The information in this bulletin is not available for Subscription
viewing via the web. If this information is important to options

you, please retain this email. Update your
profile

Unsubscribe
ITEM 1
IBM released fixes in 2002 for AIX 4.3, AIX 5.1, and AIX More News

5.2 but some customers may not have applied the fixes. Sign up for
We customized
weekly
recommend you verify all your AIX systems have the fix newsletter from
IBM
applied.

Without the fix applied, the daylight savings time
change
may not occur properly which could cause time sensitive
applications to malfunction.

Run lslpp -L bos.rte.date and compare the output with
the
following list. The fileset should be at or above the
level
in this list.

AIX 4.3.3 bos.rte.date 4.3.3.77
AIX 5.1 bos.rte.date 5.1.0.26
AIX 5.2 bos.rte.date 5.2.0.1

The fixes are available for immediate downloading at the

AIX Fix Delivery Center located at
https://techsupport.services.ibm.com/server/aix.fdc

IMPORTANT
The fix corrects the programs that created the error but

does not fix the variable setting itself. After applying

the fix you must take the following actions.

Action 1
Reset the time zone variable TZ if "echo $TZ" output
includes one or more commas. To reset the variable, run
smitty chtz.

Action 2
If you reset the time zone variable because it included
one
or more commas, then either refresh the cron daemon and
restart all applications that read the time zone
environment variable -or- reboot the system.

Reference information:

4.3 APAR IY34798 SMITTY CHTZ APPENDING 2 COMMAS AFTER TZ
5.1 APAR IY34203 SMITTY CHTZ APPENDING 2 COMMAS AFTER TZ
5.2 APAR IY35629 SMITTY CHTZ APPENDING 2 COMMAS AFTER TZ

ITEM 2
IBM relased a fix in March 2003 for AIX 5.2 but some
customers may not have applied the fix. We recommend you

verify all your AIX systems have the fix applied.

Without the fix applied, systems that use daylight
savings
time offsets may not properly change time at the correct

time. This could cause time sensitive applications to
malfunction. An offset in DST is not widely used. You do

not need to apply the fix if you do not use a DST
offset.

Run lslpp -L bos.rte.libc and compare the output with
the
following list. The fileset should be at or above the
level
in this list.

AIX 5.2 bos.rte.libc 5.2.0.10

The fixes are available for immediate downloading at the

AIX Fix Delivery Center located at
https://techsupport.services.ibm.com/server/aix.fdc

IMPORTANT
After applying the fix you must take the following
action.

Action 1
Restart all applications -or- reboot the system.

Reference information:

5.2 APAR IY39159 DEFAULT DST TZ SETTINGS WITH AN OFFSET
FAILS TO RETURN TO STD

Back to Top

IBM, eServer and pSeries are trademarks or registered
trademarks of International Business Machines
Corporation in the United States or other countries, or
both.



pic28145.gif
pic23281.gif
pic16827.gif

This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:18 EDT