Re: naive ssa loop question

From: Mark Lamport (lamport@KCMETRO.CC.MO.US)
Date: Fri Aug 01 2003 - 11:53:34 EDT


naive ssa loop questionMany ways, second drawer B1 to 1, B2 to 16. Or you can cable A1 to drawer 1 slot 1, drawer 1 slot 16 to drawer 2 slot 1, and drawer 2 slot 16 to A2. I would set up a raid array with raid_10 or raid_1 and have drawer 1 mirror drawer 2.

Mark Lamport
Sr. PeopleSoft Database Administrator
Metropolitan Community Colleges

  ----- Original Message -----
  From: Miller, Dave (I.S.)
  Newsgroups: bit.listserv.aix-l
  To: aix-l@Princeton.EDU
  Sent: Friday, August 01, 2003 10:28 AM
  Subject: naive ssa loop question

  What is the mechanism to cable to drawers (d40) of SSA disks together (i.e. 32 disks).

  I know one drawer, simple loop, would be example SSA adapter A1 to 1, A2 to 16.

  ...but what if I want two drawers in one loop?

  thanks.
  CONFIDENTIALITY NOTICE: This Email communication and any attachments may contain confidential and privileged information for the use of the designated recipients named above. If you are not the intended recipient, you are hereby notified that you have received this communication in error and that any review, disclosure, dissemination, distribution or copying of it or its contents is prohibited. If you have received this communication in error, please reply to the sender immediately or by telephone at (413) 794-0000 and destroy all copies of this communication and any attachments. For further information regarding Baystate Health System's privacy policy, please visit our Internet web site at http://www.baystatehealth.com.