Re: [Q] any way to change SSA Pdisk number?

From: Mark Lamport (lamport@KCMETRO.CC.MO.US)
Date: Fri Jul 18 2003 - 05:41:32 EDT


Yes the pdisk number might change but it doesn't matter. Pdisks are
assigned in serial number sequence. You shouldn't have any problem with
your data.

----- Original Message -----
From: "L" <leed@CHELE.CAIS.NET>
Newsgroups: bit.listserv.aix-l
To: <aix-l@Princeton.EDU>
Sent: Thursday, July 17, 2003 9:33 PM
Subject: [Q] any way to change SSA Pdisk number?

> We have SSA disk array connect to P series RS/6000. After we restore
> from "mksysb" tape, the SSA RAID configuration still keep but Pdisk number
> mess up. ROOTVG NOT on SSA. Before we restore from "mksysb" tape, the
> SSA PDISK number is 0-7 from left to right and 8-15 from left to right on
> back. After "mksysb" restore and connect SSA, the pdisk number is here
> and thier out of sequence. I know how to change "hdisk" number, but don't
> know how to change pdisk number. Anyone give me a hint?
>
> Thanks.
>



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:17:02 EDT