Re: errpt entry

From: Adams Kevin J (kevin.adams@PHS.COM)
Date: Thu Jun 12 2003 - 13:33:09 EDT


Bill,

Here's a way to narrow this down to an adapter and a number of possible
devices. This usually works, but one time on an M80 it did not work.

Take the bus number value (yours) "1000 00C2" and run:

# odmget -q value=0x100000c2 CuAt

CuAt:
        name = "pci2"
        attribute = "bus_id"
        value = "0x100000c2"
        type = "R"
        generic = ""
        rep = "n"
        nls_index = 0

Convert the interrupt level (yours) from hex to decimal: "0000 0034" = 52
and run:

# lsresource -al pci2 |grep -E "bus_intr_lvl.*52"
I scsi1 bus_intr_lvl 52 (A1)

Then get the adapter location code:

# lsdev -C|grep ^scsi1
scsi1 Available 30-68 Wide SCSI I/O Controller

Then get the devices based on the adapter's location code:

# lsdev -C|grep 30-68
scsi1 Available 30-68 Wide SCSI I/O Controller
hdisk0 Available 30-68-00-8,0 16 Bit SCSI Disk Drive
hdisk1 Available 30-68-00-9,0 16 Bit SCSI Disk Drive
hdisk2 Available 30-68-00-10,0 16 Bit SCSI Disk Drive
hdisk3 Available 30-68-00-11,0 16 Bit SCSI Disk Drive
hdisk4 Available 30-68-00-12,0 16 Bit SCSI Disk Drive
hdisk5 Available 30-68-00-13,0 16 Bit SCSI Disk Drive
ses0 Available 30-68-00-15,0 SCSI Enclosure Services Device

Kevin Adams
PacifiCare Behavioral Health
Principal Systems Analyst
AIX Certified Advanced Technical Expert

-----Original Message-----
From: Bill Verzal [mailto:BVerzal@KOMATSUNA.COM]
Sent: Thursday, June 12, 2003 8:09 AM
To: aix-l@Princeton.EDU
Subject: [aix-l] errpt entry

Anyone offer any suggestions on this ?

LABEL: INTRPPC_ERR
IDENTIFIER: DADF69E4

Date/Time: Thu Jun 12 09:52:11
Sequence Number: 9957
Machine Id: 000AF49D4C00
Node Id: sap80i
Class: H
Type: UNKN
Resource Name: SYSINTR
Resource Class: NONE
Resource Type: NONE
Location: NONE

Description
UNDETERMINED ERROR

Probable Causes
SYSTEM I/O BUS
SOFTWARE PROGRAM
ADAPTER
DEVICE

             Recommended Actions
             PERFORM PROBLEM DETERMINATION PROCEDURES

Detail Data
BUS NUMBER
0000 00C1
INTERRUPT LEVEL
0000 0023

BV
--------------------------------------------------------

Bill Verzal
AIX Administrator, Komatsu America
(847) 970-3726

This electronic message transmission, including any attachments, contains information from PacifiCare Health Systems Inc. which may be confidential or privileged. The information is intended to be for the use of the individual or entity named above. If you are not the intended recipient, be aware that any disclosure, copying, distribution or use of the contents of this information is prohibited.