From: Shekhar Dhotre (Shekhar.Dhotre@LENDLEASEREI.COM)
Date: Tue Dec 10 2002 - 10:04:15 EST
Klaus ,
After installing these filesets ,Control Workstation sees all the disks
...
spcws01@/>lslpp -l | grep devices.fcp
devices.fcp.disk.array.diag
devices.fcp.disk.array.rte
devices.fcp.disk.rte 4.3.3.0 COMMITTED FC SCSI CD-ROM, Disk,
devices.fcp.tape.rte 4.3.3.0 COMMITTED FC SCSI Tape Device
Software
devices.fcp.disk.array.rte
devices.fcp.disk.rte 4.3.3.0 COMMITTED FC SCSI CD-ROM, Disk,
devices.fcp.tape.rte 4.3.3.0 COMMITTED FC SCSI Tape Device
Software
spcws01@/>lspv
hdisk0 000258568c0e03f3 rootvg
hdisk1 000258566b48b764 rootvg
hdisk2 0002585669b5c107 spdatavg
hdisk3 00025856ab7208cd spdatavg
hdisk4 00019563817ddd9d spdatavg
hdisk5 00020032871c0b45 spdatavg
hdisk6 000120610eace3c0 spdatavg
hdisk7 000120613e62cdae None
hdisk8 0001213634c163a7 None
hdisk9 00019555d7d02fdc None
spcws01@/>lsdev -Cc disk
hdisk0 Available 10-60-00-8,0 16 Bit SCSI Disk Drive
hdisk1 Available 10-60-00-9,0 16 Bit LVD SCSI Disk Drive
hdisk2 Available 10-60-00-10,0 16 Bit SCSI Disk Drive
hdisk3 Available 10-60-00-11,0 16 Bit SCSI Disk Drive
hdisk4 Available 10-70-01 IBM FC 2105F20
hdisk5 Available 10-70-01 IBM FC 2105F20
hdisk6 Available 10-70-01 IBM FC 2105F20
hdisk7 Available 10-70-01 IBM FC 2105F20
hdisk8 Available 10-70-01 IBM FC 2105F20
hdisk9 Available 10-70-01 IBM FC 2105F20
Thank You
SD
Klaus Oberle <Klaus.Oberle@LINDE-MH.DE>
Sent by: IBM AIX Discussion List <aix-l@Princeton.EDU>
12/10/2002 03:12 AM
Please respond to IBM AIX Discussion List
To: aix-l@Princeton.EDU
cc:
Subject: Re: Disk error
Hi Shekhar,
we've had the same problem. You need to install the fileset
"devices.fcp.disk.rte" which contains
"/etc/methods/cfgscsidisk".
/klaus
---------------------------------------------------
Klaus Oberle
IT Administration
Linde Material Handling
Aschaffenburg / Germany
klaus.oberle@linde-mh.de
www.linde.com
---------------------------------------------------
Shekhar Dhotre
<Shekhar.Dhotre@LENDLE An: aix-l@Princeton.EDU
ASEREI.COM> Kopie:
Gesendet von: IBM AIX Thema: Disk error
Discussion List
<aix-l@Princeton.EDU>
07.12.2002 22:32
Bitte antworten an IBM
AIX Discussion List
Hi All,
I just assigned 6 disks from 2105 ,upon running cfgmgr -getting
following error :
spcws01@/>lsdev -Cc disk
hdisk0 Available 10-60-00-8,0 16 Bit SCSI Disk Drive
hdisk1 Available 10-60-00-9,0 16 Bit LVD SCSI Disk Drive
hdisk2 Available 10-60-00-10,0 16 Bit SCSI Disk Drive
hdisk3 Available 10-60-00-11,0 16 Bit SCSI Disk Drive
hdisk4 Defined 10-70-01 IBM FC 2105F20
hdisk5 Defined 10-70-01 IBM FC 2105F20
hdisk6 Defined 10-70-01 IBM FC 2105F20
hdisk7 Defined 10-70-01 IBM FC 2105F20
hdisk8 Defined 10-70-01 IBM FC 2105F20
hdisk9 Defined 10-70-01 IBM FC 2105F20
spcws01@/>rmdev -dl hdisk5
hdisk5 deleted
spcws01@/>rmdev -dl hdisk6
hdisk6 deleted
spcws01@/>rmdev -dl hdisk7
hdisk7 deleted
spcws01@/>rmdev -dl hdisk8
hdisk8 deleted
spcws01@/>rmdev -dl hdisk9
hdisk9 deleted
spcws01@/>cfgmgr -l fcs0
Method error (/etc/methods/cfgscsidisk -l hdisk4 ):
0514-068 Cause not known.
Method error (/etc/methods/cfgscsidisk -l hdisk5 ):
0514-068 Cause not known.
Method error (/etc/methods/cfgscsidisk -l hdisk6 ):
0514-068 Cause not known.
Method error (/etc/methods/cfgscsidisk -l hdisk7 ):
0514-068 Cause not known.
Method error (/etc/methods/cfgscsidisk -l hdisk8 ):
0514-068 Cause not known.
Method error (/etc/methods/cfgscsidisk -l hdisk9 ):
0514-068 Cause not known.
lscfg -v output ..
fcs0 10-70 FC Adapter
Part Number.................09P5079
EC Level....................A
Serial Number...............1C2180871F
Manufacturer................001C
FRU Number..................09P5080
Network Address.............10000000C92D2326
ROS Level and ID............02C03891
Device Specific.(Z0)........2002606D
Device Specific.(Z1)........00000000
Device Specific.(Z2)........00000000
Device Specific.(Z3)........02000909
Device Specific.(Z4)........FF401050
Device Specific.(Z5)........02C03891
Device Specific.(Z6)........06433891
Device Specific.(Z7)........07433891
Device Specific.(Z8)........20000000C92D2326
Device Specific.(Z9)........CS3.82A1
Device Specific.(ZA)........C1D3.82A1
Device Specific.(ZB)........C2D3.82A1
Device Specific.(YL)........P2-I4
fscsi0 10-70-01 FC SCSI I/O Controller Protocol
Device
hdisk4 10-70-01 IBM FC 2105F20
hdisk5 10-70-01 IBM FC 2105F20
hdisk6 10-70-01 IBM FC 2105F20
hdisk7 10-70-01 IBM FC 2105F20
hdisk8 10-70-01 IBM FC 2105F20
hdisk9 10-70-01 IBM FC 2105F20
Am I missing anything here ?
Thank You
SD
This e-mail may contain confidential and/or privileged information.
If you are not the intended recipient (or have received this e-mail
in error) please notify the sender immediately and destroy this e-mail.
Any unauthorised copying, disclosure or distribution of the material
in this e-mail is strictly forbidden.
Any views expressed in this message are those of the individual
sender, except where the sender specifically states them to be
the views of Linde Material Handling.
Since January 2002 we use the e-mail domain linde-mh.de instead
of linde-fh.de.
This mail has been swept for the presence of computerviruses.
This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:16:24 EDT