Re: spnode check

From: Shekhar Dhotre (Shekhar.Dhotre@LENDLEASEREI.COM)
Date: Wed Dec 04 2002 - 14:57:36 EST


Shekar ,
here is output from controlworkstaion ..

spcws01@/>spmon -d

      Controller Slot 17 Switch Switch Power supplies
Frame Responds Switch Power Clocking A B C D
----- ---------- ------- ------ -------- ----- ----- ----- -----
   1 yes yes on 0 on on on N/A
   2 yes yes on 3 on on on N/A
   3 yes yes on 3 on on on on
   4 yes yes on 3 on on on on
   5 yes yes on 3 on on on N/A

5. Checking nodes
----------------------------------- Frame 1
----------------------------------
                      Host Switch Key Env Front Panel LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
  1 1 wide on yes yes N/A no LCDs are blank no
  3 3 wide on yes yes N/A no LCDs are blank no
  5 5 wide on yes yes N/A no LCDs are blank no
  7 7 wide on yes yes N/A no LCDs are blank no
  9 9 wide on yes yes N/A no LCDs are blank no
 11 11 wide on yes yes N/A no LCDs are blank no
 13 13 wide on yes yes N/A no LCDs are blank no
 15 15 wide on yes yes N/A no LCDs are blank no

----------------------------------- Frame 2
----------------------------------
                      Host Switch Key Env Front Panel LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
  1 17 wide on yes yes N/A no LCDs are blank no
  5 21 high on yes yes N/A no LCDs are blank no
 11 27 wide on yes yes N/A no LCDs are blank no
 13 29 wide on yes yes N/A no LCDs are blank no
 15 31 wide on yes yes N/A no LCDs are blank no

----------------------------------- Frame 3
----------------------------------
                      Host Switch Key Env Front Panel LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
  1 33 wide on yes yes N/A no LCDs are blank no
  3 35 wide on yes yes N/A no LCDs are blank no
  5 37 wide on yes yes N/A no LCDs are blank no
  7 39 wide on yes yes N/A no LCDs are blank no
  9 41 wide on yes yes N/A no LCDs are blank no
 11 43 wide on yes yes N/A no LCDs are blank no
 13 45 wide on yes yes N/A no LCDs are blank no
 15 47 wide on yes yes N/A no LCDs are blank no

----------------------------------- Frame 4
----------------------------------
                      Host Switch Key Env Front Panel LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
  3 49 wide on yes yes N/A no LCDs are blank no
  5 51 high on yes yes N/A no LCDs are blank no
  9 53 wide on yes yes N/A no LCDs are blank no
 11 55 wide on yes yes N/A no LCDs are blank no
 13 57 wide on yes yes N/A no LCDs are blank no
 15 59 wide on yes yes N/A no LCDs are blank no

----------------------------------- Frame 5
----------------------------------
                      Host Switch Key Env Front Panel LCD/LED
Slot Node Type Power Responds Responds Switch Error LCD/LED Flashes
---- ---- ----- ----- -------- -------- ------- ----- ----------------
-------
  3 67 wide on yes yes N/A no LCDs are blank no
  5 69 high on yes yes N/A no LCDs are blank no
  9 73 wide on yes yes N/A no LCDs are blank no
 11 75 wide on yes yes N/A no LCDs are blank no
 13 77 wide on yes yes N/A no LCDs are blank no
 15 79 wide on yes yes N/A no LCDs are blank no

Thank You and Best regards.
^^^^^^^^^^^^^^^^^^^^^^^^
Shekhar Dhotre
Sr.Midrange Engineer.
lend lease Inc , Atlanta - 30346
Email :shekhar.dhotre@lendleaserei.com

This E-mail contains PRIVILEGED AND CONFIDENTIAL INFORMATION intended only
for the use of the Individual(s) named above. If you are not the intended
recipient of this E-mail, or the employee or agent responsible for
delivering it to the intended recipient, you are hereby notified that any
dissemination or copying of this E-mail is strictly prohibited. If you
have
received this E-mail in error, please immediately notify us .

Bill Thompson <bill.thompson@GOODYEAR.COM>
Sent by: IBM AIX Discussion List <aix-l@Princeton.EDU>
11/26/2002 01:35 PM
Please respond to IBM AIX Discussion List

        To: aix-l@Princeton.EDU
        cc:
        Subject: Re: spnode check

shekar,

The best way is with "spmon".

Here's an example (note that node 14 is powerd down)

-> spmon -G -d
1. Checking server process
    Process 34600 has accumulated 41 minutes and 17 seconds.
    Check ok

2. Opening connection to server
    Connection opened
    Check ok

3. Querying frame(s)
    2 frame(s)
    Check ok

4. Checking frames

        Controller Slot 17 Switch Switch Power supplies
Frame Responds Switch Power Clocking A B C D
----------------------------------------------------------------
  1 yes yes on 0 on on on N/A
  2 yes yes on 3 on on on on

5. Checking nodes
--------------------------------- Frame 1
-------------------------------------
Frame Node Node Host/Switch Key Env Front Panel
LCD/LED is
Slot Number Type Power Responds Switch Fail LCD/LED
Flashing
-------------------------------------------------------------------------------
  1 1 wide on yes yes normal no LEDs are blank no
  3 3 wide on yes yes normal no LEDs are blank no
  5 5 thin on yes yes normal no LEDs are blank no
  6 6 thin on yes yes normal no LEDs are blank no
  7 7 wide on yes yes normal no LEDs are blank no
  9 9 wide on yes yes normal no LEDs are blank no
 11 11 wide on yes yes normal no LEDs are blank no
 13 13 thin on yes yes normal no LEDs are blank no
 14 14 thin off no autojn normal no LEDs are blank no

--------------------------------- Frame 2
-------------------------------------
Frame Node Node Host/Switch Key Env Front Panel
LCD/LED is
Slot Number Type Power Responds Switch Fail LCD/LED
Flashing
-------------------------------------------------------------------------------
  1 17 high on yes yes normal no LCDs are blank no
  5 21 high on yes yes normal no LCDs are blank no

Bill Thompson
Sr UNIX Systems Administrator
The Goodyear Tire & Rubber Co.

Contains Confidential and/or Proprietary Information
May Not Be Copied or Disseminated Without Express Consent of The Goodyear
Tire & Rubber Company.

AIX-L Archives: http://marc.theaimsgroup.com/?l=aix-l&r=1&w=2

----- Original Message -----
From: "CHANDRASHEKAR, MANI" <MANI_CHANDRASHEKAR@FLEET.COM>
Newsgroups: bit.listserv.aix-l
To: <aix-l@Princeton.EDU>
Sent: Tuesday, November 26, 2002 1:16 PM
Subject: spnode check

> All,
>
> Is there any command or way to check from the SP control
> workstation if the SP node is alive..?, other than the ping command.
>
> Thanks..
>
> shekar......
>



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:16:23 EDT