Re: PCI - Escon Cards - H80

From: Bill Verzal (Bill_Verzal@BCBSIL.COM)
Date: Wed Nov 13 2002 - 09:13:20 EST


Yes, but you would need a second I/O drawer. So you would have a
CPU/Memory drawer, an I/O drawer (the unit comes with one), and an
expansion I/O drawer. That is the only way you will be able to have 4
adapters.

BV
--------------------------------------------------------------------------------------------------------

Bill Verzal
Technical Consultant
Forbes Technical Consulting
(312) 653-3684
bill_verzal@bcbsil.com
billverzal@imcingular.com (Pager)
888-428-4025 (Pager)
MailStop: 27.202B

|--------+------------------------------------->
| | "Mark Malins" |
| | <mark.malins@SCOTTISH-SOUTH|
| | ERN.CO.UK> |
| | Sent by: "IBM AIX |
| | Discussion List" |
| | <aix-l@Princeton.EDU> |
| | |
| | |
| | 11/13/2002 08:06 AM |
| | Please respond to "IBM AIX |
| | Discussion List" |
| | |
|--------+------------------------------------->
>----------------------------------------------------------------------------------------------------------|
  | |
  | To: aix-l@Princeton.EDU |
  | cc: |
  | Subject: Re: PCI - Escon Cards - H80 |
>----------------------------------------------------------------------------------------------------------|

Hi Bill ,
Thanks very much for the info , so basically i could put four in one H80 ?
Thanks ,
Mark .

Bill Verzal <bill_verzal@bcbsil.com> on 13/11/2002 13:55:48

Please respond to IBM AIX Discussion List <aix-l@princeton.edu>

To: aix-l@princeton.edu
cc: (bcc: Mark Malins/HAV/SSE)
Subject: Re: PCI - Escon Cards - H80

According to the adapter placement guide:

Device: FC 2751: S/390 ESCON Channel (Type 5-5)
Slot usage: 6, 11, 7, 12, 20, 25, 21, 26
# Per I/O drawer: 2
# Total Per System: 4
Hot pluggable?: Y

--------------------------------------------------------------------------------------------------------

Bill Verzal
Technical Consultant
Forbes Technical Consulting
(312) 653-3684
bill_verzal@bcbsil.com
billverzal@imcingular.com (Pager)
888-428-4025 (Pager)
MailStop: 27.202B

|--------+------------------------------------->
| | "Mark Malins" |
| | <mark.malins@SCOTTISH-SOUTH|
| | ERN.CO.UK> |
| | Sent by: "IBM AIX |
| | Discussion List" |
| | <aix-l@Princeton.EDU> |
| | |
| | |
| | 11/13/2002 04:24 AM |
| | Please respond to "IBM AIX |
| | Discussion List" |
| | |
|--------+------------------------------------->

>
----------------------------------------------------------------------------------------------------------|

  |
|
  | To: aix-l@Princeton.EDU
|
  | cc:
|
  | Subject: PCI - Escon Cards - H80
|

>
----------------------------------------------------------------------------------------------------------|

Hi all ,

 Does anyone know how many Escon cards i can get in a H80 as i have heard
it is
      only two .

Thanks and Regards,

Mark .

**********************************************************************
The information in this E-Mail is confidential and may be legally
privileged. It may not represent the views of Scottish and Southern
Energy plc.
It is intended solely for the addressees. Access to this E-Mail by
anyone else is unauthorised. If you are not the intended recipient,
any disclosure, copying, distribution or any action taken or omitted
to be taken in reliance on it, is prohibited and may be unlawful.
Any unauthorised recipient should advise the sender immediately of
the error in transmission.

Scottish Hydro-Electric, Southern Electric, SWALEC and S+S
are trading names of the Scottish and Southern Energy Group.
**********************************************************************

**********
The information contained in this communication is confidential, private,
proprietary, or otherwise privileged and is intended only for the use of
the
addressee. Unauthorized use, disclosure, distribution or copying is
strictly
prohibited and may be unlawful. If you have received this communication in
error, please notify the sender immediately at (312)653-6000 in Illinois;
(972)766-6900 in Texas; or (800)835-8699 in New Mexico.
**********

**********
The information contained in this communication is confidential, private, proprietary, or otherwise privileged and is intended only for the use of the addressee. Unauthorized use, disclosure, distribution or copying is strictly prohibited and may be unlawful. If you have received this communication in error, please notify the sender immediately at (312)653-6000 in Illinois; (972)766-6900 in Texas; or (800)835-8699 in New Mexico.
**********



This archive was generated by hypermail 2.1.7 : Wed Apr 09 2008 - 22:16:19 EDT