Re: Xwindows on an HMC

From: Inshan Singh (isingh@CO.PALM-BEACH.FL.US)
Date: Tue Apr 20 2004 - 10:30:26 EDT


Good point, I tried it as well to no avail, I did read from the Lpar
redbook that if you want that done, they recommend adding a video
adapter card to the p6*** server . Which I think is defeating the
purpose of having an HMC console....I guess I am trying to use it much
the way I did the Control Workstation for the SPs.

>>> cbaker@GOODYEAR.COM 4/19/2004 5:34:37 PM >>>
Where do you do the "xhost +" at? Can't open an xterm on the HMC and
fire that off. Can't do it in the ascii/text login
(CTRL-ALT-F1) since you don't have a DISPLAY there.

I just tried creating an "/etc/X0.hosts" file with a "+" or a specific
remote system name. Then I rebooted the HMC, but that did not
take either.

(Of course I am on a old HMC version/release 3.1.2, so that may be an
issue?)

Thanks,

Christopher M. Baker
Senior Technical Support Analyst
DSE/TCO
Goodyear Tire and Rubber Company

=================================================
Contains Confidential and/or Proprietary Information.
May not be copied or disseminated without the expressed
written consent of The Goodyear Tire & Rubber Company.
=================================================

                      Bill Verzal
                      <BVerzal@KOMATSU To:
aix-l@Princeton.EDU
                      NA.COM> cc: (bcc: Chris
Baker/NA/GDYR)
                      Sent by: IBM AIX Subject: Re: Xwindows on
an HMC
                      Discussion List
                      <aix-l@Princeton
                      .EDU>

                      04/19/04 12:25
                      PM
                      Please respond
                      to IBM AIX
                      Discussion List

As long as you are not going across the serial - yes.

Just set the display to <HMC IP ADDRESS:0.0> and run the XTERM on the
LPAR.
You might have to 'xhost', but I've done it.

BV
--------------------------------------------------------

"If everything is coming your way, then you are in the wrong lane"

Bill Verzal
AIX Administrator, Komatsu America
(847) 970-3726 - direct
(847) 970-4184 - fax

             Inshan Singh
             <isingh@CO.PALM-B
             EACH.FL.US>
To
             Sent by: IBM AIX aix-l@Princeton.EDU
             Discussion List
cc
             <aix-l@Princeton.
             EDU>
Subject
                                       Xwindows on an HMC

             04/19/2004 10:59
             AM

             Please respond to
                  IBM AIX
              Discussion List
             <aix-l@Princeton.
                   EDU>

Is it possible to bring up X windows from an Lpar on an HMC?